LX1LC1259 — Identification
ParameterValue
Product typeCoil
Product rangeTeSys
Device short nameLX1
LX1LC1259 — Electrical
ParameterValue
Control circuit voltage [Uc]125 V AC 50/60 Hz
Coil resistance (avg.)96.939 Ohm +/- 10 %
Coil inductance0.107 mH closed circuit
LX1LC1259 — Power & Thermal
ParameterValue
Power consumption (VA)12...18 VA AC 0.3 60 Hz sealed 170...230 VA AC 0.55 60 Hz inrush

Product details

The LX1LC1259 is a replacement coil from the Schneider Electric TeSys range, designed for TeSys contactors and starters that take a separable LX1-series coil. It is the control-side component that pulls the contactor in — not the power poles. The control circuit voltage is 125 V AC at 50/60 Hz, so it is a drop-in swap for any TeSys contactor originally fitted with a 125 V AC LX1 coil.

Coil resistance measures 96.939 Ohm ±10 %, which is the value a field-service tech would check with a multimeter to confirm the coil is not shorted or open before installing. The inductance is 0.107 mH in the closed-circuit (sealed) position — that is the holding state after the contactor pulls in. Power consumption is specified in VA rather than watts because the coil is an inductive load. Inrush draw is 170...230 VA at 0.55 power factor, 60 Hz — this is the surge the control transformer sees when the contactor first energizes. Sealed (holding) draw drops to 12...18 VA at 0.3 power factor, 60 Hz. That inrush-to-sealed ratio of roughly 10:1 is typical for AC-operated contactor coils and matters for sizing the control transformer: the transformer must support the inrush without voltage sag that could prevent the contactor from pulling in cleanly.

Frequently asked questions

What is the closest replacement for the LX1LC1259?

No official successor order code is listed. A current-production TeSys coil with 125 V AC control voltage may fit mechanically, but the LX1 series coil has a specific mounting interface — verify the contactor frame and coil retention method before substituting. Submit an RFQ and we can help cross-reference the physical fit.

What is the control voltage for this coil?

125 V AC at 50/60 Hz. That is the rated voltage for the coil circuit — the contactor's power poles can switch a different load voltage.

How do I source the LX1LC1259 if it is obsolete?

Through surplus or independent distributor channels. Submit an RFQ with your quantity; we will quote from available inventory. No factory lead time applies since production has ended.