Schneider Electric LX1LD1109 — Contactor & Starter Coils

Schneider Electric LX1LD1109 TeSys Integral Coil, 110 V AC

MPNLX1LD1109
Obsolete

Schneider Electric TeSys Integral, LX1LD1109 coil, 110 V AC control circuit, 350-400 VA inrush.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX1LD1109 — Identification
ParameterValue
Product typeCoil
Product rangeTeSys
Device short nameLX1
LX1LD1109 — Electrical
ParameterValue
Control circuit voltage [Uc]110 V AC
Control circuit typeAC
Control circuit voltage limitsOperational: 0.85...1.1 Uc (at Drop-out: 0.25...0.7 Uc (at <131 °F (55 °C))
Coil inductance (closed circuit)1.48 H
LX1LD1109 — Power & Thermal
ParameterValue
Inrush power (VA)350...400 VA 50 Hz cos phi 0.55
Hold-in power (VA)20...30 VA 50 Hz cos phi 0.28

Product details

Product Identity and Function

The LX1LD1109 is a replacement coil for the TeSys Integral line of combination starters, operating on a 110 V AC control circuit. This coil is the energizing element that pulls in the contactor armature, enabling the main power contacts to close. For audit purposes, the inrush power draw is 350-400 VA at 50 Hz with a cos phi of 0.55, and the hold-in consumption drops to 20-30 VA at 50 Hz with a cos phi of 0.28.

Sourcing is limited to the surplus and broker market. No direct replacement is listed by the manufacturer.

Control Circuit Specifications

The control circuit voltage is 110 V AC, with operational limits of 0.85 to 1.1 times Uc (93.5 to 121 V AC) at up to 55 °C. The drop-out voltage range is 0.25 to 0.7 times Uc (27.5 to 77 V AC) under the same temperature conditions. The inductance of the closed circuit is 1.48 H, which influences the inrush and hold-in current profile and should be considered when sizing control transformers or selecting suppression devices for the coil circuit.

Frequently asked questions

What is the closest alternative to the LX1LD1109 in the TeSys family?

The manufacturer does not list a direct pin-compatible successor for this obsolete coil. Any replacement would require verifying the control voltage, mounting dimensions, and mechanical interface against the specific Integral starter base.

What is the control voltage and power consumption of the LX1LD1109?

The control circuit is rated for 110 V AC. Inrush power is 350-400 VA at 50 Hz (cos phi 0.55), and hold-in power is 20-30 VA at 50 Hz (cos phi 0.28).

How do I source the LX1LD1109 if it is obsolete?

Submit an RFQ through our procurement desk. We source this part from the surplus and broker market on a quoted-to-order basis for legacy panel support.

MPN