Schneider Electric LX1LD415 — Contactor & Starter Coils

TeSys LX1LD415 Coil, 415-440 VAC 50 Hz, Obsolete

MPNLX1LD415
Obsolete

TeSys Integral series, coil, 415...440 V AC 50 Hz, 350...400 VA inrush, 116.46 Ohm at 20 °C.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX1LD415 — Identification
ParameterValue
Product typeCoil
Product rangeTeSys
Device short nameLX1
LX1LD415 — Electrical
ParameterValue
Control circuit voltage [Uc]415...440 V AC 50 Hz
Control circuit typeAC 50 Hz
Control circuit voltage limitsOperational: 0.85...1.1 Uc (at Drop-out: 0.25...0.7 Uc (at <131 °F (55 °C))
Coil resistance (avg.)116.46 Ohm 68 °F (20 °C)
Coil inductance (closed circuit)23.7 H
LX1LD415 — Power & Thermal
ParameterValue
Inrush power (VA)350...400 VA 50 Hz cos phi 0.55
Hold-in power (VA)20...30 VA 50 Hz cos phi 0.28

Product details

The LX1LD415 is a replacement coil for TeSys Integral combination starters — the overload-protected motor-starter family that combines a contactor, thermal overload relay, and disconnect in one enclosure. This coil specifically provides the 415...440 V AC 50 Hz control circuit voltage for the starter's magnetic operator. The control voltage limits are documented: operational range is 0.85...1.1 Uc, with dropout between 0.25...0.7 Uc at temperatures below 131 °F (55 °C). Inrush power draws 350...400 VA at 50 Hz (cos φ 0.55), dropping to 20...30 VA hold-in power (cos φ 0.28) once the magnetic circuit closes. Coil resistance measures 116.46 Ohm at 68 °F (20 °C); closed-circuit inductance is 23.7 H.

For a BOM freeze or line-down replacement, the procurement path is a one-off search through the independent channel.

Integration Constraints for the Panel OEM

This coil mounts into the TeSys Integral starter base — it is not a standalone contactor coil. The control circuit is AC 50 Hz only; do not apply DC or 60 Hz without verifying the magnetic circuit's impedance curve. The 415...440 V AC range is specific to 400 V line-to-line systems with nominal tolerance; a 480 V supply exceeds the upper limit and risks saturation or thermal damage. Inrush current at 415 V is approximately 0.84 A (350 VA / 415 V), settling to a hold-in current around 48 mA (20 VA / 415 V). The control transformer supplying this coil must be sized for the inrush peak, not the steady-state draw. The dropout voltage range (0.25...0.7 Uc) means the starter drops out between 104 and 308 V — useful for brownout ride-through assessment in the panel design.

Frequently asked questions

What is the closest alternative to LX1LD415?

No official successor or pin-compatible alternative is listed in the lifecycle record. A parametric search across TeSys Integral coils with the same 415...440 V AC 50 Hz control voltage and mechanical footprint would be required — but no direct drop-in replacement is documented.

What is LX1LD415's listed range and category?

The range is TeSys, and the category is 22384-STARTERS,INTEGRAL,ACCESS — it is a service part for the Integral starter family, not a standalone component.