Skip to main content
Schneider Electric LX4D6LD — Contactor & Starter Coils

Schneider TeSys LX4D6LD Contactor Coil, 200 V DC, 51.9 Ohm

MPNLX4D6LD
Active

Schneider Electric TeSys LX4D6LD, contactor coil, 200 V DC, 51.9 Ohm at 68 °F (20 °C), without built-in suppressor module.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LX4D6LD — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX1D6
Coil technologyWithout built-in suppressor module
LX4D6LD — Electrical
ParameterValue
Control circuit voltage [Uc]200 V DC
Coil resistance (avg.)51.9 Ohm 68 °F (20 °C)
Coil inductance (closed circuit)4.18 H
LX4D6LD — Performance & Durability
ParameterValue
Max. operating rate3600 cyc/h 140 °F (60 °C)
Mechanical durability10 Mcycles
LX4D6LD — Environmental
ParameterValue
Operating temperature23...140 °F (-5...60 °C)

Product details

The LX4D6LD is a replacement coil for the LX1D6 contactor in the TeSys range. It operates on a 200 V DC control circuit and draws its holding current through a 51.9 Ohm winding at 68 °F (20 °C). This is a bare coil — no built-in suppressor module. On a DC coil, the inductive kickback is higher than an AC equivalent, so you need an external free-wheeling diode or varistor across the coil terminals. Wire it with the cathode to the positive rail; reversed polarity shorts the diode and kills the drive transistor on the PLC output card.

Rated for 200 V DC control voltage — this is the nominal pick-up and hold voltage. On a DC coil, the inrush current is limited only by the DC resistance, so the 51.9 Ohm winding draws about 3.85 A during pick-up before the armature seats and the inductance rises to 4.18 H. That rate is the mechanical limit — the contactor's electrical life at rated load will be lower. For high-duty applications like rapid cycling conveyors, check the contactor's electrical endurance curve against your load current. Ambient temperature range of -5 to 60 °C. Within a sealed panel near a drive or transformer, ambient can exceed 50 °C — this coil is rated to handle it. Below -5 °C, the coil's pick-up voltage may shift; the DC resistance drops with cold, increasing inrush current, but the magnetic circuit's reluctance also rises. Not recommended for freezer applications without pre-heating.

Frequently asked questions

What is the closest alternative to the LX4D6LD in this family?

The LX4D6LD is the 200 V DC coil for the LX1D6 contactor. The same contactor frame accepts other coil voltages in the LX4D series — for example, the LX4D6LE at 220 V DC or LX4D6LF at 250 V DC. The physical mounting and pinout are identical; only the winding voltage changes. If 200 V DC is not available in your panel, select the closest standard DC voltage within 85–110% of nominal.

What compliance documentation is available for the LX4D6LD?

As a TeSys component, the LX4D6LD carries CE marking for the European low-voltage directive. RoHS and REACH declarations are available from Schneider Electric's documentation portal. UL and CSA listings apply to the complete contactor assembly (LX1D6), not to the replacement coil alone — the coil is a service part without independent agency certification.

MPN
LX4D6LD