Skip to main content
Schneider Electric LX4FG030 — Contactor & Starter Coils

Schneider LX4FG030 TeSys Contactor Coil, 30 V DC, Obsolete

MPNLX4FG030
Obsolete

Schneider Electric TeSys, contactor coil LX4FG030, 30 V DC, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX4FG030 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX4FG
Coil technologyWithout built-in suppressor module
LX4FG030 — Electrical
ParameterValue
Control circuit voltage [Uc]30 V DC
Control circuit typeDC wide range
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.15...0.2 Uc 131 °F (55 °C))
Coil resistance (avg.)1.25 Ohm inrush 68 °F (20 °C) 274.7 Ohm holding 68 °F (20 °C)
LX4FG030 — Performance & Durability
ParameterValue
Operating time30...40 ms closing 30...50 ms opening
LX4FG030 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX4FG030 is a replacement coil for the TeSys F range of contactors, designed to pull in and hold the contactor armature on a 30 V DC control circuit. It is a DC wide-range coil, meaning it operates across a band of control voltages rather than a single nominal value. The coil's operating time is 30 to 40 ms for closing and 30 to 50 ms for opening, which is typical for a contactor of this frame size and governs how quickly the main power contacts make or break the load circuit. At 68 °F (20 °C), the inrush resistance is 1.25 Ω, dropping to 274.7 Ω in the holding state once the armature seals — the high holding resistance keeps power dissipation low during continuous operation.

Control voltage and fit notes

The coil is rated for 30 V DC nominal control voltage, with an operational range of 0.85 to 1.1 times Uc (25.5 to 33 V DC) at 131 °F (55 °C). Dropout occurs between 0.15 and 0.2 Uc (4.5 to 6 V DC) at the same temperature. It ships without a built-in suppressor module, so if the contactor is switched by a PLC output or solid-state relay, an external flyback diode or varistor should be added across the coil terminals to protect the control circuit from the inductive kick.

Frequently asked questions

What is the closest alternative to LX4FG030?

No official successor order code is listed for this part. A replacement would need to be selected based on the contactor frame it mates with and the control voltage; the TeSys F range offers newer coil variants, but pin compatibility and mounting should be verified against the specific contactor model.

What range and category does LX4FG030 belong to?

It is part of the Schneider Electric TeSys range, classified under category 18401-WORLD SERVICE PARTS(CTR ACCESS), which covers service and replacement parts for control accessories.

What compliance documentation is available for LX4FG030?

The evidence does not list specific compliance documentation such as RoHS, REACH, UL, or IEC certificates for this part. Given its obsolete status, original documentation may be limited; verify with the supplier at time of order.

MPN