Skip to main content
Schneider Electric LX4FG045 — Contactor & Starter Coils

Schneider LX4FG045 TeSys Contactor Coil, 45 V DC, Obsolete

MPNLX4FG045
Obsolete

Schneider Electric TeSys contactor coil, LX4FG045, 45 V DC wide-range control circuit, 30...40 ms closing, 30...50 ms opening.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX4FG045 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX4FG
Coil technologyWithout built-in suppressor module
LX4FG045 — Electrical
ParameterValue
Control circuit voltage [Uc]45 V DC
Control circuit typeDC wide range
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.15...0.2 Uc 131 °F (55 °C))
Coil resistance (avg.)2.52 Ohm inrush 68 °F (20 °C) 557.8 Ohm holding 68 °F (20 °C)
LX4FG045 — Performance & Durability
ParameterValue
Operating time30...40 ms closing 30...50 ms opening
LX4FG045 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX4FG045 is a replacement contactor coil from the Schneider Electric TeSys range, designed for DC wide-range control circuits at 45 V DC nominal. It's the service part that mates with the FG-series contactor armature — not a standalone contactor, just the coil assembly you swap when the old one opens or the winding goes open-circuit. Closing time runs 30 to 40 ms, opening 30 to 50 ms. The coil draws a 2.52 Ω inrush at 20 °C, then settles to 557.8 Ω holding — that's a DC wide-range design that pulls in hard and holds on low power, which is typical for TeSys FG contactors in panel applications where you want consistent pick-up across a sagging bus. Operational voltage window is 0.85 to 1.1 times Uc at 55 °C, meaning it reliably picks up at about 38 V DC and stays sealed up to 49.5 V DC. Drop-out range is 0.15 to 0.2 Uc — roughly 6.75 to 9 V DC — so it drops cleanly on a control-power loss without chattering.

What that means for a BOM line: if this coil is on your panel's spare-parts list or a legacy machine's bill of materials, the only practical sourcing path is through surplus or broker channels. We can quote it against an RFQ — condition is everything on these, and we'll tell you what we find (new-in-box sealed surplus is the ideal; used pulls are a different conversation). No built-in suppressor module on this coil, so if your control circuit relies on a free-wheeling diode or varistor, it's external — verify the existing panel wiring includes one before you swap, or the back-EMF from the coil collapse can take out a PLC output or a 24 VDC supply.

Frequently asked questions

What replaces the LX4FG045?

No official successor order code is recorded for this specific 45 V DC coil variant. A direct replacement would need to match the FG-series armature interface and the 45 V DC wide-range control voltage. Without a Schneider-announced cross, the safest path is sourcing the original LX4FG045 from surplus.

What are the key electrical ratings for the LX4FG045?

45 V DC nominal control voltage, operational range 0.85 to 1.1 Uc (38 to 49.5 V DC), drop-out 0.15 to 0.2 Uc (6.75 to 9 V DC). Closing time 30 to 40 ms, opening 30 to 50 ms. Coil resistance 2.52 Ω inrush, 557.8 Ω holding at 20 °C.

Does the LX4FG045 include a built-in suppression module?

No. The coil is listed as 'without built-in suppressor module'. External suppression (diode or RC snubber) must be provided in the control circuit.

MPN
LX4FG045