Skip to main content
Schneider Electric LX4FG060S207 — Contactor & Starter Coils

Schneider LX4FG060S207 TeSys F Contactor Coil, 72 V DC

MPNLX4FG060S207
Obsolete

Schneider Electric TeSys F, contactor coil, LX4FG060S207, 72 V DC wide range, 800 W inrush, 5 W hold, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX4FG060S207 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX4FG
Coil technologyWithout built-in suppressor module
LX4FG060S207 — Electrical
ParameterValue
Control circuit voltage [Uc]72 V DC
Control circuit typeDC wide range
Control circuit voltage limitsOperational: 0.85...1.1 Uc (at 55 °C) Drop-out: 0.15...0.2 Uc (at 55 °C)
Coil resistance (avg.)5.07 Ohm inrush at 20 °C 984 Ohm holding at 20 °C
Coil inductance (closed circuit)85 H
LX4FG060S207 — Power & Thermal
ParameterValue
Inrush power (W)800 W (at 20 °C)
Hold-in power (W)5 W at 20 °C
LX4FG060S207 — Performance & Durability
ParameterValue
Operating time30...40 ms closing 30...50 ms opening
Max. operating rate60 cyc/h 55 °C
Mechanical durability10 Mcycles
LX4FG060S207 — Environmental
ParameterValue
Operating temperature-5...55 °C

Product details

The LX4FG060S207 is a replacement coil for TeSys F contactors, rated 72 V DC wide range control voltage. It pulls 800 W inrush at 20 °C and settles to 5 W holding power — the inrush figure tells you the coil driver needs to handle that surge without droop, or the contactor may chatter on close. Operating time runs 30...40 ms closing, 30...50 ms opening. That's fast enough for most motor switching but not for synchronous transfer switching — if you need faster break, look at a DC fast-acting contactor instead.

Key electrical constraints

Control voltage limits: operational range is 0.85...1.1 Uc at 55 °C, drop-out at 0.15...0.2 Uc at 55 °C. Coil resistance: 5.07 Ohm inrush, 984 Ohm holding at 20 °C. The inductance of the closed circuit is 85 H — that's a high inductance for a DC coil, meaning the holding current is low but the magnetic energy stored is substantial. Without a built-in suppressor module (this coil has none), you need an external flyback diode or varistor across the coil to protect the control circuit from the inductive kick.

Rated for 10 Mcycles mechanical durability at a maximum operating rate of 60 cycles per hour at 55 °C. Ambient temperature range -5...55 °C. That's standard for a TeSys F coil — it'll outlast the contactor in most panel applications.

Frequently asked questions

What replaces LX4FG060S207?

No official successor order code is published. Current TeSys F coils share the same mechanical envelope but have different coil ratings. You need to match the 72 V DC wide range and 800 W inrush to a current catalog coil — verify the replacement against your contactor's coil specifications.

What is the operating time of this coil?

Closing time is 30...40 ms, opening time is 30...50 ms.

Does this coil have a built-in suppressor?

No. The coil technology is listed as without built-in suppressor module. You must add an external flyback diode or varistor across the coil terminals to suppress the inductive voltage spike when de-energizing.

MPN