MPNLX4FG190
Obsolete

Schneider Electric TeSys LX4FG190, contactor coil, 190 V DC, 30...40 ms closing, 30...50 ms opening.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX4FG190 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX4FG
Coil technologyWithout built-in suppressor module
LX4FG190 — Electrical
ParameterValue
Control circuit voltage [Uc]190 V DC
Control circuit typeDC wide range
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.15...0.2 Uc 131 °F (55 °C))
Coil resistance (avg.)48 Ohm inrush 68 °F (20 °C) 9910 Ohm holding 68 °F (20 °C)
LX4FG190 — Performance & Durability
ParameterValue
Operating time30...40 ms closing 30...50 ms opening
LX4FG190 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX4FG190 is a replacement coil for the TeSys FG series of contactors, rated for a 190 V DC control circuit. It is a DC wide-range coil without a built-in suppressor module, meaning the installer must add external suppression (a free-wheeling diode or RC snubber) across the coil terminals to protect the control circuit from inductive kickback. Closing time is 30 to 40 ms; opening time is 30 to 50 ms. The coil draws an inrush current through 48 Ω at 20 °C, then holds through 9910 Ω at 20 °C — a typical DC economizer design that reduces holding power once the contactor is sealed. Operational voltage range is 0.85 to 1.1 Uc (161.5 to 209 V DC) at 55 °C; drop-out occurs between 0.15 and 0.2 Uc (28.5 to 38 V DC). Ambient operating temperature is -5 to 55 °C.

What to watch when specifying

Because the coil lacks a built-in suppressor, the panel builder must add one externally. A free-wheeling diode across the coil (cathode to positive) is the standard approach for DC control circuits; without it, the inductive flyback can damage PLC output cards or relay contacts driving the coil. The 190 V DC control voltage is non-standard for many panels — most DC control circuits run 24 V or 48 V. Verify that your control transformer and power supply deliver 190 V DC before ordering. The wide-range design (0.85 to 1.1 Uc) gives some margin, but a 24 V DC bus will not pull this coil in.

Frequently asked questions

What is the closest alternative to the LX4FG190?

No official successor order code has been published. Within the TeSys FG family, other coil voltage variants exist (e.g., 24 V DC, 48 V DC, 110 V DC), but none are pin-compatible substitutes without also changing the contactor base. A full contactor replacement may be the more practical path.

What is the TeSys range?

The LX4FG190 belongs to the Schneider Electric TeSys range, a broad family of motor control and protection components including contactors, overload relays, and accessories.

What compliance documentation is available for the LX4FG190?

The evidence does not list specific compliance certifications (RoHS, REACH, UL, IEC) for this order code. As an obsolete service part, original documentation may be limited; request documentation needs in your RFQ.