Schneider Electric LX4FH100 — Contactor & Starter Coils

Schneider TeSys LX4FH100 Contactor Coil, 125 V DC

MPNLX4FH100
Active

Schneider Electric TeSys F contactor coil, LX4FH, 125 V DC wide-range, 40-50 ms closing, 1 Mcycles mechanical durability, active.

$124.46Ref. price · indicative, final on quote
StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LX4FH100 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX4FH
Coil technologyWithout built-in suppressor module

Electrical

LX4FH100 — Electrical
ParameterValue
Control circuit voltage [Uc]125 V DC
Control circuit typeDC wide range
Control circuit voltage limitsOperational 0.7...1.25 Uc 158 °F (70 °C)) Drop-out 0.2...0.45 Uc 158 °F (70 °C))
Coil resistance (avg.)13.8 Ohm inrush 68 °F (20 °C) 2520 Ohm holding 68 °F (20 °C)
Coil inductance (closed circuit)353 H

Power & Thermal

LX4FH100 — Power & Thermal
ParameterValue
Inrush power (W)750 W 68 °F (20 °C))
Hold-in power (W)5 W 68 °F (20 °C)

Performance & Durability

LX4FH100 — Performance & Durability
ParameterValue
Operating time40...50 ms closing 40...65 ms opening
Max. operating rate60 cyc/h 158 °F (70 °C)
Mechanical durability1 Mcycles

Environmental

LX4FH100 — Environmental
ParameterValue
Operating temperature-67...158 °F (-55...70 °C)

Product details

TeSys F contactor coil for 125 V DC control

The LX4FH100 is a replacement coil for the TeSys F contactor range, designed for 125 V DC wide-range control circuits. It is not a complete contactor — it is the service part that goes into the contactor frame when the coil fails or the control voltage needs changing. Closing time is 40 to 50 ms; opening time is 40 to 65 ms. Mechanical durability is rated at 1 million cycles, which aligns with the contactor frame's own mechanical life in most panel applications.

Coil electrical characteristics and thermal limits

Inrush power at 20 °C is 750 W, dropping to 5 W holding. The inrush resistance is 13.8 ohms; holding resistance is 2520 ohms. The inductance of the closed circuit is 353 H — this matters for the DC-supply sizing because the inrush current spike is brief but high. The coil operates from 0.7 to 1.25 times the rated control voltage at 70 °C, and drops out between 0.2 and 0.45 Uc. Ambient temperature range is -55 to 70 °C, covering most indoor panel environments and some outdoor cabinets. Maximum operating rate is 60 cycles per hour at 70 °C — above that the coil temperature rise may exceed the insulation class. No built-in suppressor module is included; an external flyback diode or varistor should be added across the coil if the control circuit requires it.

Frequently asked questions

What is the operating time for LX4FH100?

Closing time is 40 to 50 ms; opening time is 40 to 65 ms. These times are measured at rated control voltage and ambient temperature.

What control voltage does LX4FH100 use?

It is a 125 V DC wide-range coil. The operational voltage range is 0.7 to 1.25 times Uc at 70 °C, and the drop-out range is 0.2 to 0.45 Uc.

MPN
LX4FH100