Schneider Electric LX4FH375

TeSys LX4FH375 Contactor Coil, 375 V DC, Active

MPN LX4FH375
Obsolete

TeSys F, contactor coil, LX4FH375, 375 V DC, DC low consumption, 10 Mcycles mechanical durability.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LX4FH375 specifications
ParameterValue
Control circuit typeDC low consumption
Main product or component typeContactor coil
Coil voltage375 V DC
Temp operating max55 °C
Temp operating min-5 °C
Mechanical life cycles10 Mcycles
Operating time40...50 ms closing 40...65 ms opening
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX4FH375 is a replacement coil for TeSys F contactors, wound for 375 V DC control. It is a DC low-consumption coil without a built-in suppressor module, so you will need to add a free-wheeling diode or RC snubber across the coil terminals if the driving PLC or relay card does not already handle flyback suppression. The coil draws 750 W inrush at 20 °C (about 2 A peak) and settles to 5 W holding. The holding resistance is 44 kΩ, which means the steady-state current is around 8.5 mA — low enough that a standard 24 V DC relay output can drive it through a series resistor or a dedicated DC coil driver, but the inrush spike needs a supply that can deliver the peak without droop.

Timing and mechanical life

Closing time is 40 to 50 ms; opening takes 40 to 65 ms. That spread matters if you are coordinating with upstream short-circuit protection or sequencing multiple contactors — the opening scatter can be 25 ms, so do not rely on this coil alone for precise simultaneous break. Maximum operating rate is 2400 cycles per hour at 55 °C. That is one cycle every 1.5 seconds — fine for most motor starting and resistive load switching, but if you are running a rapid-pick-and-place or a fast-reversing application, you will need to check the thermal rise in the coil.

Voltage tolerance and temperature range

The coil holds in from 0.85 to 1.1 times the rated control voltage (319 to 412 V DC) at 55 °C. Drop-out occurs between 0.15 and 0.2 Uc (56 to 75 V DC). That wide drop-out margin means the contactor will not chatter on a sagging DC bus — it stays pulled in until the voltage falls well below the nominal rail.