Schneider Electric LX4FJ027 — Contactor & Starter Coils

TeSys LX4FJ027 Contactor Coil, 27 V DC, Obsolete

MPNLX4FJ027
Active

TeSys FJ series, LX4FJ027 contactor coil, 27 V DC control voltage, obsolete lifecycle stage.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX4FJ027 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX4FJ
Coil technologyWithout built-in suppressor module
LX4FJ027 — Electrical
ParameterValue
Control circuit voltage [Uc]27 V DC
Control circuit typeDC low consumption
Control circuit voltage limitsDrop-out 0.2...0.35 Uc 131 °F (55 °C)) Operational 0.85...1.1 Uc 131 °F (55 °C))
Coil resistance (avg.)0.689 Ohm inrush 68 °F (20 °C) 183 Ohm holding 68 °F (20 °C)
LX4FJ027 — Performance & Durability
ParameterValue
Operating time45...60 ms opening 50...60 ms closing
LX4FJ027 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The TeSys LX4FJ027 is a DC low-consumption contactor coil, part of the TeSys FJ range, designed for 27 V DC control circuits. It drives the contactor's opening and closing action at 45 to 60 ms and 50 to 60 ms respectively. The coil draws 0.689 Ω inrush and 183 Ω holding resistance at 20 °C, reflecting its low-hold-power design — the holding current drops significantly once the contactor is sealed, which reduces heat buildup in the panel. Control voltage limits are specified at 0.85 to 1.1 Uc for operation and 0.2 to 0.35 Uc for dropout at 55 °C, so the coil reliably pulls in at 22.95 V DC and drops out below 9.45 V DC.

Integration Note — Coil Suppression

This coil ships without a built-in suppressor module. When integrating into a 24 V DC control circuit (the 27 V DC nominal is within the 0.85-1.1 Uc operating band), add an external flyback diode or RC snubber across the coil terminals to protect PLC output cards and relay contacts from the inductive kick during dropout.

Frequently asked questions

What is the closest replacement for LX4FJ027?

No official successor order code is listed in the manufacturer's lifecycle records. For a direct replacement, contact a distributor with the contactor frame size and coil voltage — a functionally equivalent coil from the same TeSys FJ family may exist, but compatibility must be verified against the specific contactor model.