Skip to main content
Schneider Electric LX4FJ090 — Contactor & Starter Coils

Schneider LX4FJ090 TeSys contactor coil, 90 V DC, obsolete

MPNLX4FJ090
Obsolete

Schneider Electric TeSys FJ contactor coil, LX4FJ090, 90 V DC control voltage, 45-60 ms opening / 50-60 ms closing, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX4FJ090 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX4FJ
Coil technologyWithout built-in suppressor module
LX4FJ090 — Electrical
ParameterValue
Control circuit voltage [Uc]90 V DC
Control circuit typeDC low consumption
Control circuit voltage limitsDrop-out 0.2...0.35 Uc 131 °F (55 °C)) Operational 0.85...1.1 Uc 131 °F (55 °C))
Coil resistance (avg.)8.03 Ohm inrush 68 °F (20 °C) 2137 Ohm holding 68 °F (20 °C)
LX4FJ090 — Performance & Durability
ParameterValue
Operating time45...60 ms opening 50...60 ms closing
LX4FJ090 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX4FJ090 is a replacement coil for Schneider Electric TeSys FJ contactors, rated for 90 V DC control circuits. It is a low-consumption DC coil without a built-in suppressor module, meaning an external flyback diode or RC snubber must be added across the coil terminals if the control circuit requires it — the contactor's own aux contacts share the same coil suppression path. Opening time is 45 to 60 ms; closing time is 50 to 60 ms. The inrush resistance is 8.03 Ω at 20 °C, dropping to 2137 Ω holding at the same temperature — the coil draws a brief surge to pull the armature in, then settles to a low holding current. Drop-out occurs between 0.2 and 0.35 Uc (18 to 31.5 V DC at 55 °C); the operational range is 0.85 to 1.1 Uc (76.5 to 99 V DC).

Schneider has marked the LX4FJ090 as obsolete. If the customer's approved vendor list requires a current-production part, a deviation or alternate coil selection will be needed.

The 90 V DC control voltage is specific — not a common 24 V DC or 110 V DC panel standard. Verify the control transformer or DC supply in the panel delivers 90 V DC nominal before specifying this coil. The low-consumption DC design draws less holding current than an AC coil of equivalent size, which matters if the control transformer is lightly sized or if multiple coils share a single supply. The coil's voltage limits are specified at 55 °C; derating for higher ambient is not documented here.

Frequently asked questions

What is the closest alternative to the LX4FJ090?

No official successor order code is listed in the lifecycle record. A replacement would require selecting a different TeSys coil with matching 90 V DC control voltage and mechanical fit for the FJ contactor frame — this needs a deviation from the customer's approved manufacturer list.

What is the LX4FJ090's listed range and category?

It belongs to the Schneider TeSys range and is classified under category 18401-WORLD SERVICE PARTS(CTR ACCESS), indicating it is a service/repair part rather than a standard catalog item.

What compliance documentation is available for the LX4FJ090?

The evidence does not list RoHS, REACH, UL, or IEC compliance documentation for this specific coil. Given its obsolete status, compliance declarations may be limited to the original production batch.