Skip to main content
Schneider Electric LX4FJ180 — Contactor & Starter Coils

Schneider LX4FJ180 TeSys Contactor Coil, 180 V DC, Obsolete

MPNLX4FJ180
Obsolete

Schneider Electric TeSys LX4FJ180 contactor coil, 180 V DC, DC low consumption, 45...60 ms opening, 50...60 ms closing, without built-in suppressor module.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX4FJ180 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX4FJ
Coil technologyWithout built-in suppressor module
LX4FJ180 — Electrical
ParameterValue
Control circuit voltage [Uc]180 V DC
Control circuit typeDC low consumption
Control circuit voltage limitsDrop-out 0.2...0.35 Uc 131 °F (55 °C)) Operational 0.85...1.1 Uc 131 °F (55 °C))
Coil resistance (avg.)29.9 Ohm inrush 68 °F (20 °C) 7669 Ohm holding 68 °F (20 °C)
LX4FJ180 — Performance & Durability
ParameterValue
Operating time45...60 ms opening 50...60 ms closing
LX4FJ180 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The Schneider Electric LX4FJ180 is a replacement contactor coil from the TeSys range, designed for FJ-frame contactors. It operates on 180 V DC control voltage and is a DC low-consumption type, meaning it draws a higher inrush current to pull in, then drops to a low holding current — 29.9 Ω inrush vs 7669 Ω holding at 20 °C. This is the coil only, not the full contactor; you swap it into an existing FJ contactor base.

The 180 V DC control circuit voltage is the nominal coil rating — the part pulls in reliably between 0.85 and 1.1 Uc (153–198 V DC at 55 °C) and drops out between 0.2 and 0.35 Uc (36–63 V DC at 55 °C). If your control voltage sits outside that band, the coil won't hold or won't drop cleanly. Operating time runs 45–60 ms opening, 50–60 ms closing — typical for a DC coil of this size, but worth checking if your safety circuit timing budget is tight. The coil ships without a built-in suppressor module. That means you need to add an external flyback diode or RC snubber across the coil terminals if your PLC output or relay driving it can't handle the inductive kickback. On a DC coil this size, the back-EMF spike can weld relay contacts or kill a transistor output without suppression.

Deployment context

The 180 V DC control voltage is common in battery-backed or DC-distributed control systems — think UPS-fed panels in process plants or DC bus architectures.

Frequently asked questions

What is the LX4FJ180's listed range?

It belongs to the Schneider Electric TeSys range, which covers contactors, overload relays, and accessories for motor control.

What compliance documentation is available for the LX4FJ180?

The evidence does not list RoHS, REACH, UL, or IEC certifications for this specific order code. As an obsolete part, original compliance documentation may be available from Schneider's archive, but it is not confirmed in this record.

MPN