Schneider Electric LX4FK030 — Contactor & Starter Coils

TeSys LX4FK030 Contactor Coil, 30 V DC, Obsolete

MPNLX4FK030
Obsolete

TeSys LX4FK030 contactor coil, 30 V DC, DC low consumption, 45...60 ms opening, 50...60 ms closing, without built-in suppressor module.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX4FK030 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX4FK
Coil technologyWithout built-in suppressor module
LX4FK030 — Electrical
ParameterValue
Control circuit voltage [Uc]30 V DC
Control circuit typeDC low consumption
Control circuit voltage limitsDrop-out 0.2...0.35 Uc 131 °F (55 °C)) Operational 0.85...1.1 Uc 131 °F (55 °C))
Coil resistance (avg.)0.81 Ohm inrush 68 °F (20 °C) 206.3 Ohm holding 68 °F (20 °C)
LX4FK030 — Performance & Durability
ParameterValue
Operating time45...60 ms opening 50...60 ms closing
LX4FK030 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The TeSys LX4FK030 is a contactor coil from the TeSys range, designed as a service part for replacing the coil on compatible TeSys contactors. It operates on a 30 V DC control circuit with a DC low consumption design, drawing 0.81 Ohm inrush resistance and 206.3 Ohm holding resistance at 20 °C. The coil has an opening time of 45...60 ms and a closing time of 50...60 ms, with a control voltage drop-out range of 0.2...0.35 Uc and operational range of 0.85...1.1 Uc at 55 °C. It comes without a built-in suppressor module, so you'll need to add external suppression if your circuit requires it.

The 30 V DC control voltage is the coil's nominal operating voltage — the circuit supplying it must stay within the 0.85...1.1 Uc operational limits at 55 °C to guarantee pickup. The drop-out threshold of 0.2...0.35 Uc means the contactor will release when the control voltage falls below roughly 6 to 10.5 V DC, which is a standard margin for DC coils. The operating time of 45...60 ms opening and 50...60 ms closing is typical for a DC contactor coil of this size. If your application needs faster switching, this coil won't deliver it — plan for the full window in your timing budget. The coil is rated for ambient air temperatures from 23...131 °F (-5...55 °C). If your panel runs hotter than 55 °C, you'll need to derate or relocate the coil.

Frequently asked questions

What is LX4FK030's listed range (TeSys) on this component line?

The LX4FK030 is part of the TeSys range from Schneider Electric, which covers contactors, overload relays, and accessories for motor control.

What is LX4FK030's listed category (18401-WORLD SERVICE PARTS(CTR ACCESS)) on this component line?

The category 18401-WORLD SERVICE PARTS(CTR ACCESS) indicates this is a service part — specifically a contactor coil — intended for replacement or repair of existing TeSys contactors in the field.

MPN
LX4FK030