Schneider Electric LX4FK250 — Contactor & Starter Coils

TeSys LX4FK250 Contactor Coil, 250 V DC, Obsolete

MPNLX4FK250
Obsolete

TeSys F, contactor coil, LX4FK250, 250 V DC control voltage, 10 Mcycles mechanical durability, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX4FK250 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX4FK
Coil technologyWithout built-in suppressor module
LX4FK250 — Electrical
ParameterValue
Control circuit voltage [Uc]250 V DC
Control circuit typeDC low consumption
Control circuit voltage limitsDrop-out 0.2...0.35 Uc 131 °F (55 °C)) Operational 0.85...1.1 Uc 131 °F (55 °C))
Coil resistance (avg.)56 Ohm inrush 68 °F (20 °C) 9650 Ohm holding 68 °F (20 °C)
Coil inductance (closed circuit)1350 H
LX4FK250 — Power & Thermal
ParameterValue
Inrush power (W)1100 W 68 °F (20 °C))
Hold-in power (W)6 W 68 °F (20 °C)
LX4FK250 — Performance & Durability
ParameterValue
Operating time45...60 ms opening 50...60 ms closing
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX4FK250 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX4FK250 is a replacement coil for TeSys F contactors, rated for 250 V DC control circuits. It's a DC low-consumption design — inrush draws 1100 W at 20 °C, holding settles to 6 W, with a holding resistance of 9650 Ω once the armature seals. The coil has no built-in suppressor module, so you'll need to add a free-wheeling diode or varistor across the terminals if the driving circuit doesn't already provide suppression. Opening time runs 45–60 ms, closing 50–60 ms.

Control Voltage Limits — What Stays and What Drops

The coil operates reliably between 0.85 and 1.1 Uc at 55 °C — that's 212.5 to 275 V DC. Drop-out happens between 0.2 and 0.35 Uc (50 to 87.5 V DC). If your control supply sags during a brownout, the contactor will drop out before the motor starter loses its hold-in, which is the expected behavior for a fail-safe circuit. The closed-circuit inductance of 1350 H means the coil stores significant energy — another reason to fit that external suppression diode.

Temperature and Duty Cycle Constraints

No derating curve is published in the basic spec, but the 2400 cycles/hour maximum is stated at the top of that range. If your panel runs hotter than 55 °C, this coil isn't the right fit — look for a higher-temperature variant in the TeSys range or add forced ventilation.

Frequently asked questions

What is the control voltage for this coil?

250 V DC. The operational range is 0.85 to 1.1 Uc (212.5 to 275 V DC) at 55 °C. Drop-out occurs between 0.2 and 0.35 Uc (50 to 87.5 V DC).

Does this coil include a built-in suppressor?

No. The coil technology is listed as 'without built-in suppressor module.' You must add external suppression (diode or varistor) to protect the driving circuit from the inductive kick.

What is the mechanical durability of the LX4FK250?

10 million cycles. Maximum operating rate is 2400 cycles per hour at 55 °C.