Schneider Electric LX4FL033 — Contactor & Starter Coils

Schneider Electric LX4FL033 TeSys contactor coil, 33 V DC, o

MPNLX4FL033
Obsolete

Schneider Electric TeSys range, LX4FL033 FK contactor coil, 33 V DC control circuit, 40...50 ms opening / 60...70 ms closing, without built-in suppressor module.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX4FL033 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX4FL
Coil technologyWithout built-in suppressor module
LX4FL033 — Electrical
ParameterValue
Control circuit voltage [Uc]33 V DC
Control circuit typeDC low consumption
Control circuit voltage limitsDrop-out 0.2...0.35 Uc 131 °F (55 °C)) Operational 0.85...1.1 Uc 131 °F (55 °C))
LX4FL033 — Performance & Durability
ParameterValue
Operating time40...50 ms opening 60...70 ms closing
LX4FL033 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

It is a DC low-consumption coil rated for a 33 V DC control circuit, with an opening time of 40...50 ms and a closing time of 60...70 ms. The coil ships without a built-in suppressor module, so you will need to add an external flyback diode or RC snubber across the coil terminals to protect the control circuit from the inductive kick when the coil de-energizes. The control voltage limits are specified: drop-out occurs at 0.2...0.35 Uc (about 6.6...11.6 V DC) at 131 °F (55 °C), and the operational range is 0.85...1.1 Uc (about 28...36.3 V DC) at the same temperature. Ambient operating temperature is -5...55 °C (23...131 °F).

What to watch for when specifying

Because the coil lacks a built-in suppressor, the panel builder or maintenance team must fit an external suppression device (typically a diode for DC coils) across the coil terminals. Without it, the inductive voltage spike can damage the PLC output or relay driving the coil. The 33 V DC control voltage is non-standard compared to the more common 24 V DC coils in the TeSys range. Verify that your control transformer or DC power supply delivers at least 28 V DC at the coil under load to stay within the operational range.

Frequently asked questions

What is the closest alternative to the LX4FL033?

There is no official pin-compatible replacement listed. For a drop-in fit, you would need to source the exact LX4FL033 from surplus channels. If a design change is acceptable, a standard 24 V DC TeSys coil (e.g., LX4FL024) may work with a DC-DC converter or different control voltage — but verify the mechanical fit and coil power rating against the contactor frame.

How do I source the LX4FL033?

Since it is obsolete, we source it through the surplus and broker market. Submit an RFQ with your target quantity and we will check availability across our network.