Skip to main content
Schneider Electric LX4FL075 — Contactor & Starter Coils

TeSys LX4FL075 Contactor Coil, 75 V DC, Active

MPNLX4FL075
Active

Schneider Electric TeSys F, LX4FL075, contactor coil, 75 V DC, 5 Mcycles mechanical durability.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LX4FL075 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX4FL
Coil technologyWithout built-in suppressor module

Electrical

LX4FL075 — Electrical
ParameterValue
Control circuit voltage [Uc]75 V DC
Control circuit typeDC low consumption
Control circuit voltage limitsDrop-out 0.2...0.35 Uc 131 °F (55 °C)) Operational 0.85...1.1 Uc 131 °F (55 °C))
Coil resistance (avg.)8.1 Ohm inrush 68 °F (20 °C) 1680 Ohm holding 68 °F (20 °C)
Coil inductance (closed circuit)180 H

Power & Thermal

LX4FL075 — Power & Thermal
ParameterValue
Inrush power (W)1600 W 68 °F (20 °C))
Hold-in power (W)9 W 68 °F (20 °C)

Performance & Durability

LX4FL075 — Performance & Durability
ParameterValue
Operating time40...50 ms opening 60...70 ms closing
Max. operating rate1200 cyc/h 131 °F (55 °C)
Mechanical durability5 Mcycles

Environmental

LX4FL075 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX4FL075: Rated for 75 V DC control voltage with operational limits of 0.85 to 1.1 Uc at 131 °F (55 °C) and drop-out between 0.2 and 0.35 Uc. This means the coil reliably picks up at 63.75 V DC minimum and drops out between 15 V and 26.25 V DC, ensuring clean switching without chatter in the control circuit. Opening time is 40 to 50 ms and closing time is 60 to 70 ms, which suits standard motor starting and disconnection sequences in TeSys F contactors. Mechanical durability is rated at 5 million cycles, reflecting the expected service life under normal switching conditions before mechanical wear-out.

Electrical characteristics and thermal performance

Inrush power consumption is 1600 W at 68 °F (20 °C), dropping to 9 W holding power once the contactor is sealed. The inrush resistance is 8.1 Ohm, rising to 1680 Ohm in the holding state. This high inrush-to-hold ratio is typical for DC-operated contactor coils and must be accounted for in the control transformer sizing. The coil has no built-in suppressor module, so an external flyback diode or RC snubber must be added across the coil terminals to protect the DC control circuit from voltage spikes during de-energization. Inductance of the closed circuit is 180 H, which influences the time constant of the coil circuit and the sizing of any external suppression components. Ambient operating temperature range is 23 to 131 °F (-5 to 55 °C), suitable for standard indoor panel environments without derating.

Frequently asked questions

What is LX4FL075's listed range on this component line?

The LX4FL075 belongs to the TeSys range, specifically the TeSys F series of contactors and accessories.

What compliance documentation does this brand provide for LX4FL075?

As a Schneider Electric TeSys component, the LX4FL075 is manufactured under standard industrial compliance frameworks. Specific RoHS, REACH, UL, and IEC declarations are available from the manufacturer upon request through the RFQ process.

MPN
LX4FL075