Skip to main content
Schneider Electric LX4FL080 — Contactor & Starter Coils

Schneider Electric LX4FL080 TeSys contactor coil, 80 V DC

MPNLX4FL080
Active

Schneider Electric TeSys contactor coil, LX4FL080, 80 V DC control circuit, 40...50 ms opening / 60...70 ms closing, without built-in suppressor module.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LX4FL080 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX4FL
Coil technologyWithout built-in suppressor module

Electrical

LX4FL080 — Electrical
ParameterValue
Control circuit voltage [Uc]80 V DC
Control circuit typeDC low consumption
Control circuit voltage limitsDrop-out 0.2...0.35 Uc 131 °F (55 °C)) Operational 0.85...1.1 Uc 131 °F (55 °C))

Performance & Durability

LX4FL080 — Performance & Durability
ParameterValue
Operating time40...50 ms opening 60...70 ms closing

Environmental

LX4FL080 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX4FL080 is a replacement contactor coil from the Schneider Electric TeSys range, designed for DC low-consumption control circuits at 80 V DC. It's the drop-in energizing component for TeSys contactors that use the FK-style coil platform — you swap the coil, not the whole contactor, when the control voltage changes or the original coil fails.

Coil pull-in and drop-out are governed by the control circuit voltage limits: the coil operates reliably between 0.85 and 1.1 Uc (68 to 88 V DC) at 55 °C, and drops out between 0.2 and 0.35 Uc (16 to 28 V DC). That drop-out window matters for applications where the DC bus sags under load — if your bus holds above 28 V during a brownout, the contactor stays sealed. Opening time is 40 to 50 ms; closing is 60 to 70 ms, which is typical for a DC-operated power contactor and fast enough for most motor and resistive load switching. This coil ships without a built-in suppressor module. That means you need to add an external flyback diode or RC snubber across the coil terminals if the control circuit drives the coil from a PLC output or solid-state relay — the inductive kick from the coil can damage electronics without suppression.

The LX4FL080 is listed as an active product. It is a service part — not a full contactor assembly — so it is typically quoted to order rather than sitting on a shelf.

Frequently asked questions

What TeSys range does the LX4FL080 belong to?

The LX4FL080 is part of the Schneider Electric TeSys range, specifically the FK-style contactor coil family. It is catalogued under category 18401-WORLD SERVICE PARTS(CTR ACCESS), meaning it is a service/accessory part for contactors, not a standalone contactor.

Does the LX4FL080 include a built-in surge suppressor?

No. The coil technology is listed as 'without built-in suppressor module'. An external suppression device (flyback diode or RC snubber) must be added to the control circuit to protect switching elements from the inductive voltage spike when the coil de-energizes.

What compliance documentation is available for the LX4FL080?

As a Schneider Electric TeSys component, the LX4FL080 is manufactured to comply with applicable IEC/EN standards for contactor accessories. Specific declarations (RoHS, REACH, UL, IEC) are available through the Schneider Electric documentation portal or upon request via the RFQ process — the evidence does not list individual certification marks, so confirm the exact certificate needed for your jurisdiction.

MPN
LX4FL080