Schneider Electric LX4FL090 — Contactor & Starter Coils

Schneider TeSys LX4FL090 Contactor Coil, 90 V DC

MPNLX4FL090
Active

Schneider Electric TeSys LX4FL090, contactor coil, 90 V DC control voltage, 40...50 ms opening, 60...70 ms closing, without built-in suppressor module.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LX4FL090 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX4FL
Coil technologyWithout built-in suppressor module

Electrical

LX4FL090 — Electrical
ParameterValue
Control circuit voltage [Uc]90 V DC
Control circuit typeDC low consumption
Control circuit voltage limitsDrop-out 0.2...0.35 Uc 131 °F (55 °C)) Operational 0.85...1.1 Uc 131 °F (55 °C))

Performance & Durability

LX4FL090 — Performance & Durability
ParameterValue
Operating time40...50 ms opening 60...70 ms closing

Environmental

LX4FL090 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The Schneider Electric LX4FL090 is a replacement contactor coil from the TeSys range, designed to drive the FK-series contactor armature. It operates on a 90 V DC control circuit with low-consumption DC coil technology and no built-in suppressor module — so if your existing circuit relied on a free-wheel diode or RC snubber at the coil terminals, that external suppression must be retained or added per the panel schematic. Opening time is 40 to 50 ms; closing time is 60 to 70 ms. Those figures matter when you're coordinating contactor timing in a motor starter or reversing circuit — the coil's mechanical travel sets the minimum interval before the auxiliary contacts change state.

Control voltage limits and dropout behaviour

The coil is rated for a control circuit voltage of 90 V DC, with an operational range of 0.85 to 1.1 Uc at 131 °F (55 °C). Dropout occurs between 0.2 and 0.35 Uc at the same temperature. That means the contactor will hold in down to about 76.5 V DC and will reliably drop out below about 31.5 V DC — important for brownout ride-through or for verifying that a low-voltage condition actually opens the power contacts. Ambient operating temperature is -5 to 55 °C (23 to 131 °F). If the panel ambient runs higher, the coil's thermal rise plus ambient may shift the dropout point; per the datasheet, the limits are stated at 55 °C, so derating above that is not covered by these figures.

Frequently asked questions

What is the closest alternative to the LX4FL090 in the TeSys family?

The closest peer is another LX4FL variant with a different control voltage — for example, LX4FL048 (48 V DC) or LX4FL024 (24 V DC). The mechanical footprint and timing are identical; only the coil voltage changes. There is no pin-compatible substitute with the same 90 V DC rating outside the LX4FL family.

What range and category does the LX4FL090 belong to?

It belongs to the TeSys range and is classified under category 18401 — World Service Parts (CTR ACCESS), meaning it is a service / replacement coil rather than a new-build line item.

Does the LX4FL090 include a built-in suppressor module?

No. The coil technology is listed as 'without built-in suppressor module'. External suppression (diode or RC snubber) must be provided by the panel wiring if required.

MPN
LX4FL090