Skip to main content
Schneider Electric LX4FL150 — Contactor & Starter Coils

TeSys LX4FL150 Contactor Coil, 150 V DC, Active

MPNLX4FL150
Active

TeSys LX4FL150 contactor coil, 150 V DC, 40-50 ms opening time, active production.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LX4FL150 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX4FL
Coil technologyWithout built-in suppressor module

Electrical

LX4FL150 — Electrical
ParameterValue
Control circuit voltage [Uc]150 V DC
Control circuit typeDC low consumption
Control circuit voltage limitsDrop-out 0.2...0.35 Uc 131 °F (55 °C)) Operational 0.85...1.1 Uc 131 °F (55 °C))

Performance & Durability

LX4FL150 — Performance & Durability
ParameterValue
Operating time40...50 ms opening 60...70 ms closing

Environmental

LX4FL150 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The TeSys LX4FL150 is a replacement contactor coil from the TeSys range, designed for DC low-consumption control circuits at 150 V DC. It's the service part you pull when the original coil on an FK-series contactor fails or you're building a spare kit for a panel that runs on a 150 V DC control bus. Opening time is 40 to 50 ms, closing time 60 to 70 ms — that's the mechanical stroke, not the arc extinction. If your application needs faster break than 50 ms, this coil won't get you there; you'd need a different contactor family with a faster armature.

Control voltage limits — the real fit check

The coil is rated for 150 V DC nominal, but the real operating window is 0.85 to 1.1 Uc at 131 °F (55 °C) — that's 127.5 to 165 V DC. Drop-out happens between 0.2 and 0.35 Uc, so 30 to 52.5 V DC. If your control supply sags below 127 V under load, the coil may drop out unexpectedly. No built-in suppressor module, so you'll need an external flyback diode or RC snubber across the coil to protect the PLC output or relay driving it.

Frequently asked questions

What control voltage does the LX4FL150 use?

150 V DC nominal, with an operating range of 127.5 to 165 V DC at 55 °C. Drop-out occurs between 30 and 52.5 V DC.

Does the LX4FL150 include a built-in suppressor module?

No — the coil technology is listed as 'without built-in suppressor module'. You'll need to add an external flyback diode or RC snubber across the coil terminals to suppress the inductive kickback.

MPN
LX4FL150