Skip to main content
Schneider Electric LX4FL400 — Contactor & Starter Coils

Schneider LX4FL400 TeSys Contactor Coil, 400 V DC, Obsolete

MPNLX4FL400
Obsolete

Schneider Electric TeSys FK contactor coil, LX4FL400, 400 V DC control circuit, 40-50 ms opening / 60-70 ms closing, without built-in suppressor module.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LX4FL400 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX4FL
Coil technologyWithout built-in suppressor module
LX4FL400 — Electrical
ParameterValue
Control circuit voltage [Uc]400 V DC
Control circuit typeDC low consumption
Control circuit voltage limitsDrop-out 0.2...0.35 Uc 131 °F (55 °C)) Operational 0.85...1.1 Uc 131 °F (55 °C))
LX4FL400 — Performance & Durability
ParameterValue
Operating time40...50 ms opening 60...70 ms closing
LX4FL400 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

It is a replacement coil for TeSys contactors that use this FK coil platform, not a standalone contactor. The coil operates with an opening time of 40 to 50 ms and a closing time of 60 to 70 ms. It has no built-in suppressor module, so external suppression (e.g., a free-wheeling diode) must be added across the coil when driven by a DC supply to protect the control circuit from inductive kickback. Control voltage limits are specified: dropout occurs at 0.2 to 0.35 Uc at 131 °F (55 °C), and operational pickup requires 0.85 to 1.1 Uc at the same temperature. Ambient operating temperature range is 23 to 131 °F (-5 to 55 °C).

Integration Note — Panel Fit and Wiring

This coil mounts onto the TeSys FK contactor frame. The 400 V DC control voltage is non-standard for many panel designs that run 24 V DC control — verify your control transformer and DC supply before specifying. The coil's DC low-consumption design draws less inrush than an AC coil of equivalent rating, which simplifies the DC supply sizing. Because the coil lacks a built-in suppressor, the panel builder must add a flyback diode (e.g., 1N4007 or similar rated for the coil current) across the coil terminals, cathode to positive. This prevents the voltage spike on de-energization from damaging PLC output cards or relay contacts driving the coil.

Frequently asked questions

What is the control voltage for this coil?

The LX4FL400 is a 400 V DC control coil. It operates on a DC low-consumption control circuit at 400 V nominal.

Does this coil include a built-in suppressor?

No. The coil is specified as 'Without built-in suppressor module'. An external free-wheeling diode must be added across the coil for DC operation.

What are the opening and closing times?

Opening time is 40 to 50 ms; closing time is 60 to 70 ms.

MPN