Skip to main content
Schneider Electric LX5FJW11 — Contactor & Starter Coils

Schneider Electric LX5FJW11

MPNLX5FJW11
Obsolete

TeSys F - contactor coil - LX5FJ - 24 V DC

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LX5FJW11 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX5FJ
Coil technologyWithout built-in suppressor module
LX5FJW11 — Electrical
ParameterValue
Control circuit voltage [Uc]24 V DC
Control circuit typeDC wide range
Control circuit voltage limitsDrop-out 0.2...0.45 Uc 158 °F (70 °C)) Operational 0.75...1.25 Uc 158 °F (70 °C))
Coil resistance (avg.)56 Ohm 68 °F (20 °C)
Coil inductance (closed circuit)0.049 H
LX5FJW11 — Power & Thermal
ParameterValue
Inrush power (W)290...860 W 68 °F (20 °C))
Hold-in power (W)16...47 W 68 °F (20 °C)
LX5FJW11 — Performance & Durability
ParameterValue
Operating time20 ms opening 60 ms closing
Max. operating rate60 cyc/h 158 °F (70 °C)
Mechanical durability1 Mcycles
LX5FJW11 — Environmental
ParameterValue
Operating temperature-67...158 °F (-55...70 °C)
LX5FJW11 — Other specifications
ParameterValue
Quantity per setSet of 2 (coil with resistors)
MPN