Schneider Electric LX9FF042 — Contactor & Starter Coils

TeSys LX9FF042 contactor coil, 42 V AC, obsolete

MPNLX9FF042
Obsolete

TeSys F specific contactor coil, LX9FF042, 42 V AC 40..400 Hz low consumption, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX9FF042 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FF
Coil technologyWithout built-in suppressor module
LX9FF042 — Electrical
ParameterValue
Control circuit voltage [Uc]42 V AC 40...400 Hz
Control circuit typeAC 40...400 Hz low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.2...0.55 Uc 131 °F (55 °C))
Coil resistance (avg.)2.5 Ohm inrush 68 °F (20 °C) 64.45 Ohm holding 68 °F (20 °C)
Coil inductance (closed circuit)0.3 H
LX9FF042 — Power & Thermal
ParameterValue
Inrush power (VA)690...855 VA 40...400 Hz (at 68 °F (20 °C))
Hold-in power (VA)6.6...8.1 VA 40...400 Hz (at 68 °F (20 °C))
Heat dissipation5.9...7.2 W
LX9FF042 — Performance & Durability
ParameterValue
Operating time130 ms opening 35 ms closing
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX9FF042 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX9FF042 is a specific contactor coil from the TeSys F range, designed as a replacement or spare coil for TeSys F contactors. It is a low-consumption AC coil rated at 42 V AC, 40 to 400 Hz, without a built-in suppressor module. The coil draws an inrush power of 690 to 855 VA and holds at 6.6 to 8.1 VA at 68 °F (20 °C). Average resistance is 2.5 Ω inrush and 64.45 Ω holding at the same temperature. Closed-circuit inductance is 0.3 H. Operating time is 130 ms opening and 35 ms closing. Heat dissipation runs 5.9 to 7.2 W.

The part is obsolete. Any replacement must match the 42 V AC control voltage, low-consumption profile, and TeSys F mounting interface.

The 42 V AC control circuit voltage is the key fit parameter: this coil operates between 0.85 and 1.1 Uc and drops out between 0.2 and 0.55 Uc at 131 °F (55 °C). The 2400 cycles/hour maximum at 55 °C sets the thermal duty limit. In a high-speed pick-and-place or conveyor switching application, stay under that rate to avoid exceeding the 5.9 to 7.2 W heat dissipation capacity. The 10 Mcycle mechanical life means the coil itself is not the wear item in most installations — the contactor's main contacts will typically need replacement first.