Skip to main content
Schneider Electric LX9FF090 — Contactor & Starter Coils

TeSys LX9FF090 Contactor Coil, 90 V AC, Obsolete

MPNLX9FF090
Obsolete

TeSys F, specific contactor coil, LX9FF090, 90 V AC 40..400 Hz low consumption, 10 Mcycles mechanical durability.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX9FF090 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FF
Coil technologyWithout built-in suppressor module
LX9FF090 — Electrical
ParameterValue
Control circuit voltage [Uc]90 V AC 40...400 Hz
Control circuit typeAC 40...400 Hz low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.35...0.55 Uc 131 °F (55 °C))
Coil resistance (avg.)9.34 Ohm inrush 68 °F (20 °C) 285.1 Ohm holding 68 °F (20 °C)
LX9FF090 — Power & Thermal
ParameterValue
Inrush power (VA)690...855 VA 40...400 Hz (at 68 °F (20 °C))
Hold-in power (VA)6.6...8.1 VA 40...400 Hz (at 68 °F (20 °C))
Heat dissipation5.9...7.2 W
LX9FF090 — Performance & Durability
ParameterValue
Operating time130 ms opening 35 ms closing
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX9FF090 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The TeSys LX9FF090 is a specific contactor coil for the TeSys F range, designed to replace or service the coil on a TeSys F contactor frame. It operates on a 90 V AC control circuit at 40 to 400 Hz, with low-consumption AC coil technology — no built-in suppressor module, so you add your own RC snubber or varistor across the coil if the application needs one. Opening time is 130 ms, closing time 35 ms. The coil draws 690 to 855 VA inrush at 20 °C, then holds at 6.6 to 8.1 VA. Average resistance is 9.34 Ω inrush and 285.1 Ω holding at 20 °C. Heat dissipation runs 5.9 to 7.2 W. The control voltage limits are 0.85 to 1.1 Uc for operation and 0.35 to 0.55 Uc for drop-out at 55 °C.

This part is listed as Obsolete by the manufacturer. No official successor order code exists.

Frequently asked questions

What is the closest pin-compatible alternative to LX9FF090 in this component family?

The manufacturer has not published a direct successor order code for this coil. A pin-compatible alternative would need to match the TeSys F contactor frame and the 90 V AC coil voltage — verify the mounting and electrical interface against your existing contactor before ordering any substitute.

What is LX9FF090's listed range on this component line?

It belongs to the TeSys range.

What is LX9FF090's listed category?

The category is 22341-CONTACTOR,D,K,&F ACCESS.

MPN
LX9FF090