Skip to main content
Schneider Electric LX9FF170 — Contactor & Starter Coils

Schneider LX9FF170 TeSys F contactor coil, 170 V AC

MPNLX9FF170
Active

Schneider Electric TeSys F, specific contactor coil, LX9FF170, 170 V AC 40..400 Hz low consumption.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LX9FF170 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FF
Coil technologyWithout built-in suppressor module
LX9FF170 — Electrical
ParameterValue
Control circuit voltage [Uc]170 V AC 40...400 Hz
Control circuit typeAC 40...400 Hz low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.35...0.55 Uc 131 °F (55 °C))
Coil resistance (avg.)37.55 Ohm inrush 68 °F (20 °C) 1453 Ohm holding 68 °F (20 °C)
LX9FF170 — Power & Thermal
ParameterValue
Inrush power (VA)690...855 VA 40...400 Hz (at 68 °F (20 °C))
Hold-in power (VA)6.6...8.1 VA 40...400 Hz (at 68 °F (20 °C))
Heat dissipation5.9...7.2 W
LX9FF170 — Performance & Durability
ParameterValue
Operating time130 ms opening 35 ms closing
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX9FF170 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX9FF170 is a specific contactor coil from the TeSys F range, designed for 170 V AC control circuits at 40 to 400 Hz with low consumption technology. It is a replacement or spare coil for TeSys F contactors, not a complete contactor — the coil alone, without a built-in suppressor module. Rated for continuous duty in a control panel environment, the LX9FF170 operates within an ambient temperature range of -5 to 55 °C.

The coil draws 690 to 855 VA inrush at 20 °C, then settles to 6.6 to 8.1 VA holding — the inrush figure determines the sizing of the control transformer and the contactor's pick-up reliability, while the hold-in VA governs continuous heat load in the panel. Coil resistance measures 37.55 ohms inrush and 1453 ohms holding at 20 °C, which confirms the low-hold-power design and helps with PLC output drive calculations if a relay interface is used. Operational voltage range is 0.85 to 1.1 times Uc at 55 °C; drop-out occurs between 0.35 and 0.55 Uc. Opening time is 130 ms, closing time 35 ms — the asymmetry matters for sequencing: the slower opening gives the arc more time to extinguish on break, while the fast close minimizes pre-strike wear on the main contacts.

Thermal and mechanical endurance

Heat dissipation runs 5.9 to 7.2 W in the holding state — this is the continuous thermal load the coil adds to the enclosure, relevant for panel thermal calculations when multiple coils are energized simultaneously.

Frequently asked questions

What is the TeSys range and the category for this part?

The LX9FF170 belongs to the TeSys range, Schneider Electric's family of contactors and motor starters. Its category is 22341 — Contactor, D, K, & F Access, which covers replacement coils and auxiliary blocks for the TeSys D, K, and F contactor frames.

What compliance documentation is available for the LX9FF170?

As a Schneider Electric TeSys component, the LX9FF170 is manufactured under standard industrial control compliance frameworks (RoHS, REACH, CE, and applicable IEC/EN standards for contactor accessories). Specific declaration documents are available through the Schneider Electric product documentation portal by searching the LX9FF170 order code.

MPN