MPNLX9FF280
Obsolete

TeSys F, specific contactor coil, LX9FF280, 280 V AC 40..400 Hz low consumption, 130 ms opening / 35 ms closing.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX9FF280 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FF
Coil technologyWithout built-in suppressor module
LX9FF280 — Electrical
ParameterValue
Control circuit voltage [Uc]280 V AC 40...400 Hz
Control circuit typeAC 40...400 Hz low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.2...0.55 Uc 131 °F (55 °C))
Coil resistance (avg.)91.33 Ohm inrush 68 °F (20 °C) 3368 Ohm holding 68 °F (20 °C)
Coil inductance (closed circuit)14 H
LX9FF280 — Power & Thermal
ParameterValue
Inrush power (VA)690...855 VA 40...400 Hz (at 68 °F (20 °C))
Hold-in power (VA)6.6...8.1 VA 40...400 Hz (at 68 °F (20 °C))
Heat dissipation5.9...7.2 W
LX9FF280 — Performance & Durability
ParameterValue
Operating time130 ms opening 35 ms closing
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX9FF280 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX9FF280 is a specific contactor coil from the TeSys F range, designed to operate a TeSys F contactor with a 280 V AC control circuit at 40 to 400 Hz. It's a low-consumption coil — meaning it draws 690 to 855 VA inrush and only 6.6 to 8.1 VA holding — sized for continuous duty in a panel. The coil's operating time is 130 ms opening and 35 ms closing, which is standard for this frame size.

The coil is rated for 280 V AC control voltage, with an operational range of 0.85 to 1.1 Uc (238 to 308 V AC) at 131 °F (55 °C). Drop-out occurs between 0.2 and 0.55 Uc (56 to 154 V AC) — so if your control voltage sags below that threshold, the contactor will drop out. That's important for brownout-prone sites. Average coil resistance is 91.33 ohms inrush and 3368 ohms holding at 68 °F (20 °C). The closed-circuit inductance is 14 H. Heat dissipation runs 5.9 to 7.2 W — modest for a contactor coil this size, but worth checking against your panel's thermal budget if it's densely packed. This coil uses AC low-consumption technology without a built-in suppressor module. If your control circuit requires surge suppression (for PLC outputs or sensitive electronics), you'll need to add an external RC snubber or varistor across the coil terminals.

The LX9FF designation identifies this as a specific contactor coil for the TeSys F contactor series. The TeSys F range covers motor starters and contactors from about 9 to 38 A in AC-3 duty. This coil is the 280 V AC variant — other voltages in the LX9FF family cover 110 V, 220 V, 380 V, and 415 V AC. The coil is a service part, not a standalone contactor; it mounts onto the contactor's magnet assembly.

Frequently asked questions

What replaces the LX9FF280?

There is no official successor order code listed for this part. Because it's a specific coil for a specific TeSys F contactor frame, a replacement would require either finding NOS (new old stock) inventory or replacing the entire contactor assembly with a current-production unit.

What is the operating temperature range for this coil?

The ambient air temperature for operation is -5 to 55 °C (23 to 131 °F).

Does this coil have a built-in suppressor module?

No, the coil technology is listed as 'without built-in suppressor module'. External suppression is needed if driving from a PLC output or sensitive control circuit.