Skip to main content
Schneider Electric LX9FF300 — Contactor & Starter Coils

Schneider Electric LX9FF300 TeSys F Contactor Coil, 300 V AC

MPNLX9FF300
Active

Schneider Electric TeSys F, specific contactor coil, LX9FF300, 300 V AC 40..400 Hz low consumption, 130 ms opening 35 ms closing.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX9FF300 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FF
Coil technologyWithout built-in suppressor module
LX9FF300 — Electrical
ParameterValue
Control circuit voltage [Uc]300 V AC 40...400 Hz
Control circuit typeAC 40...400 Hz low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.35...0.55 Uc 131 °F (55 °C))
Coil resistance (avg.)114.1 Ohm inrush 68 °F (20 °C) 4098 Ohm holding 68 °F (20 °C)
LX9FF300 — Power & Thermal
ParameterValue
Inrush power (VA)690...855 VA 40...400 Hz (at 68 °F (20 °C))
Hold-in power (VA)6.6...8.1 VA 40...400 Hz (at 68 °F (20 °C))
Heat dissipation5.9...7.2 W
LX9FF300 — Performance & Durability
ParameterValue
Operating time130 ms opening 35 ms closing
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX9FF300 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX9FF300 is a specific replacement coil for the TeSys F contactor range, rated 300 V AC at 40 to 400 Hz with low-hold consumption. It is the part that pulls the contactor in and keeps it sealed — no built-in suppressor, so you add the RC snubber or varistor externally per the panel design. Opening time is 130 ms, closing time 35 ms. The coil draws 690 to 855 VA inrush, then drops to 6.6 to 8.1 VA holding. Average resistance measures 114.1 Ω inrush and 4098 Ω holding at 20 °C. Heat dissipation runs 5.9 to 7.2 W once sealed. The control voltage limits are 0.85 to 1.1 Uc for pickup and 0.35 to 0.55 Uc for dropout at 55 °C.

Sourcing reality — obsolete, sourced to order

If you are filling a BOM line or replacing a failed coil in a live panel, the RFQ is the correct next step.

Frequently asked questions

What is the control voltage and coil type for the LX9FF300?

The LX9FF300 is a 300 V AC coil rated 40 to 400 Hz, low-consumption type. It has no built-in suppressor module, so you add external suppression. Inrush is 690 to 855 VA; holding is 6.6 to 8.1 VA.

What are the operating times and mechanical life?

Opening time is 130 ms, closing time 35 ms. Mechanical durability is 10 million cycles, with a maximum operating rate of 2400 cycles per hour at 55 °C.

What is the ambient temperature range for this coil?

The LX9FF300 is rated for operation from -5 to 55 °C. Control voltage limits are 0.85 to 1.1 Uc for pickup and 0.35 to 0.55 Uc for dropout at 55 °C.