Skip to main content
Schneider Electric LX9FF350 — Contactor & Starter Coils

TeSys LX9FF350 Contactor Coil, 350 V AC, Obsolete

MPNLX9FF350
Obsolete

Schneider Electric TeSys F LX9FF350, specific contactor coil, 350 V AC 40..400 Hz low consumption, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX9FF350 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FF
Coil technologyWithout built-in suppressor module
LX9FF350 — Electrical
ParameterValue
Control circuit voltage [Uc]350 V AC 40...400 Hz
Control circuit typeAC 40...400 Hz low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.35...0.55 Uc 131 °F (55 °C))
Coil resistance (avg.)139.7 Ohm inrush 68 °F (20 °C) 5139 Ohm holding 68 °F (20 °C)
LX9FF350 — Power & Thermal
ParameterValue
Inrush power (VA)690...855 VA 40...400 Hz (at 68 °F (20 °C))
Hold-in power (VA)6.6...8.1 VA 40...400 Hz (at 68 °F (20 °C))
Heat dissipation5.9...7.2 W
LX9FF350 — Performance & Durability
ParameterValue
Operating time130 ms opening 35 ms closing
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX9FF350 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX9FF350 is a specific contactor coil from the Schneider Electric TeSys F range, designed as a replacement or spare coil for TeSys F contactors. It operates on a 350 V AC control circuit at 40 to 400 Hz and is classed as a low-consumption coil, drawing 690 to 855 VA inrush and 6.6 to 8.1 VA holding at 68 °F (20 °C). The coil's opening time is 130 ms and closing time is 35 ms, with a maximum operating rate of 2400 cycles per hour at 131 °F (55 °C). Mechanical durability is rated at 10 million cycles, and heat dissipation sits between 5.9 and 7.2 W.

Control voltage limits and coil characteristics

The control circuit voltage limits are defined at 131 °F (55 °C): operational range is 0.85 to 1.1 times Uc (298 to 385 V AC), and dropout occurs between 0.35 and 0.55 Uc (123 to 193 V AC). This means the coil will reliably pick up at 298 V and must see voltage drop below 193 V to release, which is typical for AC-operated contactor coils in industrial panels. Average coil resistance is 139.7 ohms inrush and 5139 ohms holding at 68 °F (20 °C). The coil uses AC technology without a built-in suppressor module, so if your application requires surge suppression, you will need to add an external RC snubber or varistor across the coil terminals.

Deployment context

As a TeSys F contactor coil, this part mounts directly onto the corresponding TeSys F contactor frame inside a motor control center or panel enclosure. The coil's 350 V AC control voltage is common in European and some Asian industrial installations where the control transformer secondary is 400 V or 415 V, stepped down through a tap.

Frequently asked questions

What replaces the LX9FF350?

No official replacement order code is provided in the manufacturer's lifecycle record. For an exact-fit replacement, the only option is to source from surplus or broker channels against an RFQ.

What is the control voltage range for reliable operation?

At 131 °F (55 °C), the operational voltage range is 0.85 to 1.1 times Uc (298 to 385 V AC). Dropout occurs between 0.35 and 0.55 Uc (123 to 193 V AC).

Does this coil include a built-in surge suppressor?

No, the coil technology is listed as without built-in suppressor module. An external RC snubber or varistor should be added if surge suppression is required.

MPN
LX9FF350