Skip to main content
Schneider Electric LX9FG042 — Contactor & Starter Coils

TeSys LX9FG042 Contactor Coil, 42 V AC, Obsolete

MPNLX9FG042
Obsolete

Schneider Electric TeSys F series, LX9FG042 specific contactor coil, 42 V AC 40-400 Hz low consumption, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX9FG042 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FG
Coil technologyWithout built-in suppressor module
LX9FG042 — Electrical
ParameterValue
Control circuit voltage [Uc]42 V AC 40...400 Hz
Control circuit typeAC 40...400 Hz low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.2...0.55 Uc 131 °F (55 °C))
Coil resistance (avg.)1.75 Ohm inrush 68 °F (20 °C) 45.61 Ohm holding 68 °F (20 °C)
Coil inductance (closed circuit)0.25 H
LX9FG042 — Power & Thermal
ParameterValue
Inrush power (VA)950...1180 VA 40...400 Hz (at 68 °F (20 °C))
Hold-in power (VA)8.9...10.9 VA 40...400 Hz (at 68 °F (20 °C))
Heat dissipation8...9.8 W
LX9FG042 — Performance & Durability
ParameterValue
Operating time130 ms opening 35 ms closing
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX9FG042 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The Schneider Electric LX9FG042 is a specific replacement coil for the TeSys F contactor range, designed for a 42 V AC control circuit operating across 40 to 400 Hz. It is a low-consumption AC coil without a built-in suppressor module, meaning the installer must fit an external RC snubber or varistor across the coil if driving it from a PLC output or solid-state relay that needs protection from back-EMF. The coil draws an inrush of 950 to 1180 VA at 68 °F (20 °C) and holds at 8.9 to 10.9 VA, which is typical for a large-frame contactor; the holding power is low enough to run warm without excessive panel heat.

Sourcing Reality: Obsolete, Sourced to Order

We source it against an RFQ; there is no factory lead time to quote.

Control voltage is 42 V AC, with an operational range of 0.85 to 1.1 Uc (35.7 to 46.2 V) at 131 °F (55 °C). Drop-out occurs between 0.2 and 0.55 Uc (8.4 to 23.1 V). If your control transformer is feeding a long 42 V circuit, voltage drop at the coil terminals must stay above 35.7 V or the contactor may chatter. Opening time is 130 ms; closing time is 35 ms. That 130 ms opening delay is slow for a safety circuit — this coil is not suitable for an emergency-stop contactor that must drop out in under 100 ms. That is a standard industrial duty cycle — fine for conveyors and pumps, not for high-speed pick-and-place. Heat dissipation runs 8 to 9.8 W. In a sealed, uncooled panel with multiple contactors running continuously, that heat adds up. Leave an air gap or use a ventilated enclosure if you are grouping several TeSys F contactors.

Deployment Context: Panel Integration

The TeSys F contactor range is a DIN-rail or screw-panel mounted frame common in motor control centres and industrial control panels. The LX9FG042 coil is the replaceable actuator that snaps onto the contactor base.

Frequently asked questions

What is the closest alternative to the LX9FG042?

There is no official successor listed in the lifecycle record. A surplus or broker channel is the only source for this exact order code.

What is the control voltage and frequency range for this coil?

It is a 42 V AC coil rated for 40 to 400 Hz. The operational voltage limits are 0.85 to 1.1 Uc (35.7 to 46.2 V) at 131 °F (55 °C).

Does this coil include a built-in suppressor?

No. The coil is specified as without built-in suppressor module. An external RC snubber or varistor must be added if the driving circuit requires back-EMF protection.

What compliance documentation is available for the LX9FG042?

The lifecycle record does not include RoHS, REACH, UL, or IEC documentation for this obsolete part. Contact us with your RFQ and we can check archive records on request.

MPN
LX9FG042