Schneider Electric LX9FG090 — Contactor & Starter Coils

TeSys LX9FG090 contactor coil, 90 V AC, obsolete

MPNLX9FG090
Obsolete

TeSys F, specific contactor coil, LX9FG090, 90 V AC 40..400 Hz low consumption, obsolete lifecycle.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX9FG090 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FG
Coil technologyWithout built-in suppressor module
LX9FG090 — Electrical
ParameterValue
Control circuit voltage [Uc]90 V AC 40...400 Hz
Control circuit typeAC 40...400 Hz low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.35...0.55 Uc 131 °F (55 °C))
Coil resistance (avg.)6.92 Ohm inrush 68 °F (20 °C) 220 Ohm holding 68 °F (20 °C)
LX9FG090 — Power & Thermal
ParameterValue
Inrush power (VA)950...1180 VA 40...400 Hz (at 68 °F (20 °C))
Hold-in power (VA)8.9...10.9 VA 40...400 Hz (at 68 °F (20 °C))
Heat dissipation8...9.8 W
LX9FG090 — Performance & Durability
ParameterValue
Operating time130 ms opening 35 ms closing
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX9FG090 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The Telemecanique LX9FG090 is a specific contactor coil from the TeSys F range, designed to mount on TeSys F contactors. It operates on a 90 V AC control circuit at 40 to 400 Hz, drawing 950 to 1180 VA inrush and 8.9 to 10.9 VA holding at 68 °F (20 °C). The coil has no built-in suppressor module, so external suppression (RC snubber or varistor) must be added across the coil terminals when driven by a PLC output or electronic timer to prevent voltage spikes from damaging the driver. Opening time is 130 ms, closing time 35 ms, with a maximum operating rate of 2400 cycles per hour at 131 °F (55 °C).

Key electrical parameters for fit

Control voltage limits: operational range is 0.85 to 1.1 Uc (76.5 to 99 V AC) at 131 °F (55 °C); dropout occurs between 0.35 and 0.55 Uc (31.5 to 49.5 V AC). This means the coil will hold in reliably down to about 77 V AC but will drop out if voltage sags below roughly 32 V AC. Average coil resistance: 6.92 Ω inrush, 220 Ω holding at 68 °F (20 °C). Heat dissipation runs 8 to 9.8 W, which must be considered in enclosure thermal calculations, especially in a densely packed panel. Ambient operating temperature range is 23 to 131 °F (-5 to 55 °C).

Deployment context

The coil is a replacement or spare part for existing TeSys F contactor assemblies — not a standalone component.

Frequently asked questions

What replaces the LX9FG090?

No official successor order code is provided in the lifecycle record. For a replacement, consult the current TeSys F coil catalog at the same 90 V AC control voltage and verify mechanical fit with your contactor frame.

What are the key electrical ratings for the LX9FG090?

Control voltage is 90 V AC 40-400 Hz. Inrush power is 950-1180 VA; holding power is 8.9-10.9 VA. Coil resistance is 6.92 Ω inrush and 220 Ω holding at 68 °F (20 °C). Opening time 130 ms, closing time 35 ms.

Does the LX9FG090 include a built-in suppressor module?

No. The coil is specified without a built-in suppressor module. External suppression must be added when driven by electronic outputs.

MPN