Schneider Electric LX9FG150 — Contactor & Starter Coils

TeSys LX9FG150 Contactor Coil, 150 V AC, Obsolete

MPNLX9FG150
Obsolete

TeSys F, specific contactor coil, LX9FG150, 150 V AC 40..400 Hz low consumption, 130 ms opening 35 ms closing, 10 Mcycles mechanical durability.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX9FG150 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FG
Coil technologyWithout built-in suppressor module
LX9FG150 — Electrical
ParameterValue
Control circuit voltage [Uc]150 V AC 40...400 Hz
Control circuit typeAC 40...400 Hz low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.35...0.55 Uc 131 °F (55 °C))
Coil resistance (avg.)21.26 Ohm inrush 68 °F (20 °C) 860 Ohm holding 68 °F (20 °C)
LX9FG150 — Power & Thermal
ParameterValue
Inrush power (VA)950...1180 VA 40...400 Hz (at 68 °F (20 °C))
Hold-in power (VA)8.9...10.9 VA 40...400 Hz (at 68 °F (20 °C))
Heat dissipation8...9.8 W
LX9FG150 — Performance & Durability
ParameterValue
Operating time130 ms opening 35 ms closing
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX9FG150 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The TeSys F LX9FG150 is a specific replacement coil for the TeSys F contactor range, wound for 150 V AC control at 40 to 400 Hz. It is a low-consumption design, drawing 950 to 1180 VA inrush and holding at 8.9 to 10.9 VA — the inrush figure governs the control transformer sizing; the hold-in figure determines the continuous heat load on the panel. Opening time is 130 ms, closing 35 ms, which sets the minimum off-time for anti-jog or fast-reversing circuits: you need at least 130 ms of de-energized dwell before re-closing, or the armature may not fully reset.

The coil dissipates 8 to 9.8 W continuously when energized. That heat must be accounted for in the enclosure thermal budget — in a sealed panel with multiple contactors running, the cumulative dissipation from these coils can raise internal ambient above the 55 °C operating limit. The coil has no built-in suppressor module, so an external RC snubber or varistor across the coil terminals is required to limit switching transients that could couple into the control wiring. The control voltage limits are 0.85 to 1.1 Uc for pickup (127.5 to 165 V AC) and 0.35 to 0.55 Uc for dropout (52.5 to 82.5 V AC) at 55 °C — the dropout margin is generous, so the coil will hold in through moderate sags, but it also means a downstream undervoltage relay may drop out before the contactor does.

Frequently asked questions

What is the closest pin-compatible alternative to the LX9FG150?

No official successor order code is listed in the product record. A parametric replacement would need to match the 150 V AC 40-400 Hz control voltage, the low-consumption coil profile, and the physical mounting interface of the TeSys F contactor frame it is designed for. A cross-reference must be verified by matching the specific contactor base part number.

What are the key electrical ratings of the LX9FG150 coil?

Control voltage is 150 V AC 40-400 Hz. Inrush power is 950 to 1180 VA; hold-in power is 8.9 to 10.9 VA. Coil resistance is 21.26 ohms inrush and 860 ohms holding at 20 °C. Opening time is 130 ms, closing time 35 ms. Mechanical durability is 10 million cycles.

MPN
LX9FG150