Skip to main content
Schneider Electric LX9FG350 — Contactor & Starter Coils

TeSys LX9FG350 Contactor Coil, 350 V AC, Obsolete

MPNLX9FG350
Obsolete

TeSys F, specific contactor coil, LX9FG350, 350 V AC 40..400 Hz low consumption.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX9FG350 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FG
Coil technologyWithout built-in suppressor module
LX9FG350 — Electrical
ParameterValue
Control circuit voltage [Uc]350 V AC 40...400 Hz
Control circuit typeAC 40...400 Hz low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.35...0.55 Uc 131 °F (55 °C))
Coil resistance (avg.)102.3 Ohm inrush 68 °F (20 °C) 3886 Ohm holding 68 °F (20 °C)
LX9FG350 — Power & Thermal
ParameterValue
Inrush power (VA)950...1180 VA 40...400 Hz (at 68 °F (20 °C))
Hold-in power (VA)8.9...10.9 VA 40...400 Hz (at 68 °F (20 °C))
Heat dissipation8...9.8 W
LX9FG350 — Performance & Durability
ParameterValue
Operating time130 ms opening 35 ms closing
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX9FG350 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX9FG350 is a specific contactor coil from the TeSys F range, designed for 350 V AC control circuits at 40–400 Hz with low-consumption draw. It is the replacement coil for TeSys F contactors that use this dedicated coil platform — not a universal fit, but the exact OEM part for the frame. Rated control voltage is 350 V AC; operational limits are 0.85–1.1 Uc at 131 °F (55 °C), with drop-out at 0.35–0.55 Uc. Opening time is 130 ms, closing time 35 ms. The coil draws 950–1180 VA inrush at 68 °F (20 °C) and settles to 8.9–10.9 VA holding. Heat dissipation runs 8–9.8 W, so panel ventilation around the contactor stack matters if you are grouping several on a DIN rail. The coil ships without a built-in suppressor module — if your application needs transient suppression (common on PLC-driven contactors), plan to add an external RC snubber or varistor across the coil terminals.

Because it is a specific coil for the TeSys F frame, there is no direct drop-in successor with the same mounting and electrical profile. If you are maintaining an existing panel, the LX9FG350 is the correct replacement for a failed coil. For new designs, consider whether the contactor assembly itself should be migrated to a current TeSys range.

Integration Notes

Operating temperature range is 23 to 131 °F (-5 to 55 °C). If the coil is in a non-ventilated enclosure near other heat sources, stay below the upper end to avoid accelerated insulation aging. The 8–9.8 W dissipation is continuous — it adds up in a multi-contactor panel.

Frequently asked questions

Does this coil include a built-in suppressor?

No. The LX9FG350 ships without a built-in suppressor module. For inductive load switching or PLC-driven circuits, an external RC snubber or varistor should be added across the coil terminals.

What is the operating temperature range?

The LX9FG350 is rated for ambient air temperatures from 23 to 131 °F (-5 to 55 °C).

How do I source this obsolete part?

Submit an RFQ. As an obsolete part, it is sourced through surplus and broker inventory rather than factory stock. We can quote available quantities against your order.

MPN
LX9FG350