Skip to main content
Schneider Electric LX9FH3202 — Contactor & Starter Coils

TeSys LX9FH3202 Contactor Coil, 316-340 V AC, Obsolete

MPNLX9FH3202
Active

TeSys F, specific contactor coil, LX9FH3202, 316..340 V AC 40..400 Hz, low consumption, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX9FH3202 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FH
Coil technologyWithout built-in suppressor module
LX9FH3202 — Electrical
ParameterValue
Control circuit voltage [Uc]316...340 V AC 40...400 Hz
Control circuit typeAC 40...400 Hz low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.35...0.55 Uc 131 °F (55 °C))
Coil resistance (avg.)136.1 Ohm inrush 68 °F (20 °C) 2892 Ohm holding 68 °F (20 °C)
LX9FH3202 — Power & Thermal
ParameterValue
Inrush power (VA)560...660 VA 40...400 Hz (at 68 °F (20 °C))
Hold-in power (VA)8...10 VA 40...400 Hz (at 68 °F (20 °C))
Heat dissipation8.4...10.4 W
LX9FH3202 — Performance & Durability
ParameterValue
Operating time25 ms opening 45 ms closing
Max. operating rate3600 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX9FH3202 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX9FH3202 is a specific contactor coil from the TeSys F range, designed as the control-circuit component for TeSys F contactors. It operates on a 316 to 340 V AC control circuit at 40 to 400 Hz, with a low-consumption design that draws 8 to 10 VA holding power and 560 to 660 VA inrush at 68 °F (20 °C). The coil's average resistance measures 136.1 Ω inrush and 2892 Ω holding at the same temperature.

The 316 to 340 V AC control voltage range means this coil is intended for line-voltage control circuits in regions where nominal supply is 400 V three-phase, typically tapped phase-to-phase at 347 V. The 0.85 to 1.1 Uc operational limit (268 to 374 V AC at 131 °F) and 0.35 to 0.55 Uc drop-out range (110 to 187 V AC) define the voltage window for reliable pick-up and guaranteed release — critical for coordinating with undervoltage protection schemes. The opening time of 25 ms and closing time of 45 ms are fast enough for general motor switching but not for high-speed inverter bypass applications where sub-10 ms response is needed. Heat dissipation of 8.4 to 10.4 W means the coil contributes measurable thermal load inside the enclosure. In a densely packed panel, this must be factored into the thermal budget — especially if the contactor cycles frequently at the maximum rate. The coil ships without a built-in suppressor module. For inductive-load switching, an external RC snubber or varistor across the coil terminals is required to limit voltage spikes and comply with EMC directives — a standard practice for AC control circuits.

As a TeSys F specific contactor coil, this part is deployed inside motor control centers and industrial control panels where TeSys F contactors are installed. It is the replaceable coil assembly for the contactor's electromagnetic drive — when the coil fails, you swap this component rather than the entire contactor.

Frequently asked questions

What is the closest alternative to LX9FH3202?

The lifecycle record does not list an official successor order code. A parametric search for a TeSys F specific contactor coil with a 316-340 V AC 40-400 Hz low-consumption coil would be the starting point for identifying a replacement, but pin-to-pin compatibility and mounting dimensions must be verified against the existing contactor assembly.

What is the TeSys range for this part?

The LX9FH3202 belongs to the TeSys F range, which is Schneider Electric's line of heavy-duty contactors and associated accessories for motor control and power switching.

What compliance documentation is available for LX9FH3202?

The evidence does not list specific compliance certifications (RoHS, REACH, UL, IEC) for this order code. As an obsolete part, original manufacturer declarations may be difficult to obtain; surplus stock may carry original markings, but this should be confirmed at the time of sourcing.

MPN
LX9FH3202