Schneider Electric LX9FJ937 — Contactor & Starter Coils

TeSys LX9FJ937 Contactor Coil, 440 V AC/DC, Obsolete

MPNLX9FJ937
Obsolete

TeSys F, specific contactor coil, 440 V AC 40...400 Hz low consumption, LX9FJ937.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX9FJ937 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FJ
Coil technologyWithout built-in suppressor module
LX9FJ937 — Electrical
ParameterValue
Control circuit voltage [Uc]440 V AC 40...400 Hz 440 V DC
Control circuit typeAC 40...400 Hz low consumption DC low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.3...0.5 Uc 131 °F (55 °C))
Coil resistance (avg.)386 Ohm inrush 68 °F (20 °C) 3690 Ohm holding 68 °F (20 °C)
Coil inductance (closed circuit)19 H
LX9FJ937 — Power & Thermal
ParameterValue
Inrush power (VA)500 VA 40...400 Hz (at 68 °F (20 °C))
Hold-in power (VA)23 VA 40...400 Hz (at 68 °F (20 °C))
Heat dissipation11.4...13.9 W
LX9FJ937 — Performance & Durability
ParameterValue
Operating time60 ms opening 50 ms closing
Max. operating rate3600 cyc/h 158 °F (70 °C)
Mechanical durability10 Mcycles
LX9FJ937 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX9FJ937 is a specific contactor coil from the TeSys F range, designed to operate a TeSys F contactor at 440 V AC (40–400 Hz) or 440 V DC with low consumption. It pulls in at 500 VA inrush and holds at 23 VA, with a closed-circuit inductance of 19 H. Opening time is 60 ms, closing 50 ms — figures that matter when coordinating contactor timing in a motor starter or transfer scheme.

The control circuit accepts 440 V AC across 40–400 Hz or 440 V DC, with operational limits of 0.85–1.1 Uc at 55 °C and drop-out between 0.3–0.5 Uc. That drop-out range is wide enough to ensure the contactor releases cleanly on a sagging control supply — important for undervoltage protection schemes. The coil draws 386 Ω inrush and 3690 Ω holding at 20 °C, so verify your control transformer sizing: the inrush VA (500 VA) is the peak load, not the steady-state draw. Heat dissipation runs 11.4–13.9 W depending on control voltage and duty. In a densely packed panel, that heat adds up — allow ventilation or spacing around the contactor if multiple coils are energized continuously. The coil comes without a built-in suppressor module. If your control circuit uses solid-state outputs or a PLC driving the contactor, add an external RC snubber or varistor across the coil to suppress the inductive kick on de-energization.

Where it belongs in the panel

This coil mounts onto a TeSys F contactor frame — it is the interchangeable coil that lets you field-change the control voltage without replacing the whole contactor. No wiring changes at the power terminals, just the control leads to the coil.

Frequently asked questions

What is the control voltage for this coil?

440 V AC at 40–400 Hz or 440 V DC. The operational limits are 0.85–1.1 Uc at 55 °C, and drop-out occurs between 0.3–0.5 Uc.

Does this coil include a built-in suppressor?

No. The coil technology is listed as without built-in suppressor module. An external RC snubber or varistor is recommended when driven by solid-state outputs.

What are the switching times for the LX9FJ937?

Opening time is 60 ms, closing time is 50 ms. These are the mechanical operating times of the coil itself.