Schneider Electric LX9FK913 — Contactor & Starter Coils

TeSys LX9FK913 specific contactor coil, 30-32 V AC/DC, activ

MPNLX9FK913
Active

Schneider Electric TeSys F, specific contactor coil LX9FK913, 30-32 V AC/DC, 60 ms opening, 20 ms closing, without built-in suppressor module.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LX9FK913 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FK
Coil technologyWithout built-in suppressor module

Electrical

LX9FK913 — Electrical
ParameterValue
Control circuit voltage [Uc]30...32 V DC 30...32 V AC
Control circuit typeAC 40...400 Hz low consumption DC low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.3...0.5 Uc 131 °F (55 °C))
Coil inductance (closed circuit)0.22 H

Power & Thermal

LX9FK913 — Power & Thermal
ParameterValue
Inrush power (W)470 W 68 °F (20 °C))
Hold-in power (W)29 W 68 °F (20 °C)
Heat dissipation15...18.3 W

Performance & Durability

LX9FK913 — Performance & Durability
ParameterValue
Operating time60 ms opening 20 ms closing
Max. operating rate3600 cyc/h 158 °F (70 °C)
Mechanical durability10 Mcycles

Environmental

LX9FK913 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX9FK913 is a specific contactor coil from the Schneider Electric TeSys F range, designed as a replacement or spare coil for TeSys F contactors. It operates on a control circuit voltage of 30...32 V AC or DC, with a 60 ms opening time and a 20 ms closing time — the opening speed matters for arc extinction on inductive loads, so if you're swapping a coil in a motor-starting circuit, that 60 ms is what governs contact separation.

Control circuit and coil technology

This coil is supplied without a built-in suppressor module, so you'll need to add an external RC snubber or varistor across the coil terminals if the control circuit drives inductive loads or if you're seeing noise on the PLC output. The control circuit type accepts AC 40...400 Hz or DC low consumption, meaning it works on standard 50/60 Hz line or DC supplies without derating. Inrush power hits 470 W at 20 °C, then settles to a hold-in consumption of 29 W — that inrush spike is brief but enough to sag a small 24 VDC supply if you're firing multiple coils simultaneously.

Operating limits and durability

Rated for an ambient temperature range of -5...55 °C, so it's fine inside a ventilated panel but not for direct outdoor exposure. The control voltage limits are tight: operational range is 0.85...1.1 Uc at 55 °C, and drop-out occurs between 0.3...0.5 Uc — meaning if your DC supply dips below about 9 V (on a 30 V nominal), the coil drops out and the contactor opens.

Frequently asked questions

What is the control voltage for this coil?

The control circuit voltage is 30...32 V AC or DC. The operational limits are 0.85...1.1 Uc at 55 °C, and drop-out occurs between 0.3...0.5 Uc.

Does this coil include a built-in suppressor module?

No, the LX9FK913 is supplied without a built-in suppressor module. An external RC snubber or varistor should be added if the control circuit drives inductive loads.

What is the operating temperature range?

The ambient air temperature for operation is -5...55 °C.

MPN