Schneider Electric LX9FK914 — Contactor & Starter Coils

Schneider LX9FK914 TeSys F Contactor Coil, 28-31 V DC

MPNLX9FK914
Active

Schneider Electric TeSys F series, specific contactor coil LX9FK914, 28-31 V DC low consumption, 550 VA inrush / 31 VA hold, 60 ms opening / 50 ms closing.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LX9FK914 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FK
Coil technologyWithout built-in suppressor module

Electrical

LX9FK914 — Electrical
ParameterValue
Control circuit voltage [Uc]28...31 V DC
Control circuit typeAC 40...400 Hz low consumption DC low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.3...0.5 Uc 131 °F (55 °C))

Power & Thermal

LX9FK914 — Power & Thermal
ParameterValue
Inrush power (VA)550 VA (at 68 °F (20 °C))
Hold-in power (VA)31 VA (at 68 °F (20 °C))
Heat dissipation15...18.3 W

Performance & Durability

LX9FK914 — Performance & Durability
ParameterValue
Operating time60 ms opening 50 ms closing
Max. operating rate3600 cyc/h 158 °F (70 °C)
Mechanical durability10 Mcycles

Environmental

LX9FK914 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

Coil for TeSys F contactors — 28-31 V DC low-consumption variant

The LX9FK914 is a specific replacement coil for the TeSys F contactor range, designed for 28-31 V DC control circuits with low-consumption electronics that pull 550 VA inrush and drop to 31 VA holding power at 20 °C. That inrush-to-hold ratio matters for DC-supply sizing: the coil draws a heavy initial pulse, then settles to a fraction of that. The control circuit accepts both AC (40-400 Hz) and DC supplies, but the voltage range is DC-only — 28-31 V DC operational, with dropout between 0.3 and 0.5 Uc (roughly 8.4-15.5 V DC).

Switching timing and thermal budget

Opening takes 60 ms, closing 50 ms — standard for a DC-operated coil of this size. The coil dissipates 15-18.3 W continuously, which means the panel designer needs to account for that heat in a confined enclosure, especially if multiple contactors are ganged.

Mechanical endurance and operating rate

That rate is the mechanical limit — actual electrical life depends on the load switched (AC-1, AC-3, etc.) and will typically be lower for motor loads.

Suppressor note — external diode required

This coil ships without a built-in suppressor module. For DC control circuits, a free-wheeling diode must be added across the coil terminals to prevent voltage spikes when de-energizing. Without it, the inductive kick can damage PLC outputs or relay contacts driving the coil. Schneider offers a range of add-on suppressor modules (e.g., the LA4 series) that clip onto the contactor base.

Frequently asked questions

What is the control voltage range for this coil?

The LX9FK914 operates at 28-31 V DC. Dropout occurs between 0.3 and 0.5 Uc (approximately 8.4-15.5 V DC).

Does this coil include a built-in surge suppressor?

No, the LX9FK914 ships without a built-in suppressor module. An external free-wheeling diode or suppressor (e.g., Schneider LA4 series) must be added for DC control circuits.

What is the heat dissipation of this coil?

The LX9FK914 dissipates 15-18.3 W continuously. Account for this thermal load in panel design, especially in confined enclosures with multiple contactors.

What is the mechanical endurance rating?

Rated for 10 million mechanical cycles at a maximum operating rate of 3600 cycles per hour at 70 °C.