Schneider Electric LX9FK915 — Contactor & Starter Coils

Schneider Electric LX9FK915 TeSys F Contactor Coil, 32-34 VD

MPNLX9FK915
Active

Schneider Electric TeSys F specific contactor coil, LX9FK915, 32-34 VDC low consumption, 60 ms opening / 50 ms closing, 10 Mcycles mechanical durability.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LX9FK915 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FK
Coil technologyWithout built-in suppressor module

Electrical

LX9FK915 — Electrical
ParameterValue
Control circuit voltage [Uc]32...34 V DC
Control circuit typeAC 40...400 Hz low consumption DC low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.3...0.5 Uc 131 °F (55 °C))

Power & Thermal

LX9FK915 — Power & Thermal
ParameterValue
Inrush power (VA)550 VA (at 68 °F (20 °C))
Hold-in power (VA)31 VA (at 68 °F (20 °C))
Heat dissipation15...18.3 W

Performance & Durability

LX9FK915 — Performance & Durability
ParameterValue
Operating time60 ms opening 50 ms closing
Max. operating rate3600 cyc/h 158 °F (70 °C)
Mechanical durability10 Mcycles

Environmental

LX9FK915 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

Coil for a TeSys F contactor

The LX9FK915 is a specific replacement coil for the TeSys F range of contactors, built for a 32-34 V DC control circuit. It's a low-consumption coil without a built-in suppressor module, so if your application needs flyback suppression on the DC side, you'll add that externally at the panel wiring. Opening time is 60 ms, closing time 50 ms — these are the mechanical switching speeds of the contactor armature driven by this coil. For a mill environment, that's fast enough to clear a fault on a motor starter without nuisance tripping on a voltage dip. On a continuous-process line running at 3600 cycles per hour — the maximum operating rate at 70 °C — that works out to roughly 2800 hours of service before the coil's mechanical life is consumed. In practice, a contactor in a pump starter that cycles once per hour will see the coil outlast the contactor's electrical life.

Power draw and thermal budget

Inrush power is 550 VA at 20 °C, dropping to 31 VA holding power. That's a typical AC coil characteristic even on a DC-rated coil — the inrush slams the armature home, and the hold-in winding takes over. Heat dissipation runs 15-18.3 W once sealed. In a densely packed panel, that's enough heat to derate adjacent devices if the cabinet isn't ventilated. Control voltage limits are 0.85 to 1.1 Uc for operation at 55 °C, and dropout between 0.3 and 0.5 Uc at the same temperature. That dropout threshold is tight enough to prevent chatter on a sagging 24 V bus, but wide enough to drop out cleanly on a hard fault.

Frequently asked questions

What is the control voltage for this coil?

The LX9FK915 is rated for 32-34 V DC control voltage, with an operating range of 0.85-1.1 Uc at 55 °C.

Does this coil include a built-in suppressor module?

No, the LX9FK915 is specified without a built-in suppressor module. External flyback suppression must be added for DC control circuits.

What is the operating temperature range for this coil?

The LX9FK915 operates in an ambient air temperature range of -5 to 55 °C.