Schneider Electric LX9FL916 — Contactor & Starter Coils

TeSys LX9FL916 specific contactor coil, 38-41 V DC, obsolete

MPNLX9FL916
Obsolete

TeSys F specific contactor coil, LX9FL916, 38..41 V DC low consumption, 48 W hold-in, 733 W inrush, 22.8..27.8 W dissipation.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX9FL916 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FL
Coil technologyWithout built-in suppressor module
LX9FL916 — Electrical
ParameterValue
Control circuit voltage [Uc]38...41 V DC
Control circuit typeAC 40...400 Hz low consumption DC low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.3...0.5 Uc 131 °F (55 °C))
LX9FL916 — Power & Thermal
ParameterValue
Inrush power (W)733 W 68 °F (20 °C))
Hold-in power (W)48 W 68 °F (20 °C)
Heat dissipation22.8...27.8 W
LX9FL916 — Performance & Durability
ParameterValue
Operating time60 ms opening 20 ms closing
Max. operating rate1800 cyc/h 158 °F (70 °C)
Mechanical durability5 Mcycles
LX9FL916 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX9FL916 is a specific contactor coil from the TeSys F range, designed as a field-replaceable coil for TeSys F contactors. It operates on a 38...41 V DC control circuit and draws 48 W holding power, with an inrush of 733 W at 20 °C. The coil has no built-in suppressor module — if your application requires flyback suppression, you add it externally.

The 38...41 V DC control voltage is tight — operational limits are 0.85...1.1 Uc at 55 °C, so the supply must stay between roughly 32 V and 45 V DC. Drop-out occurs at 0.3...0.5 Uc (about 11...20 V DC), which means the coil releases reliably on a sagging supply. Opening time is 60 ms, closing 20 ms — fast enough for most motor switching but not for high-speed cycling above 1800 cycles/hour at 70 °C. Heat dissipation runs 22.8...27.8 W continuously. In a closed panel with multiple contactors, that adds up — account for the thermal load in your enclosure sizing. Mechanical durability is 5 million cycles, so the coil itself is not the wear-out item in a typical motor-starting application.

Frequently asked questions

What is the closest pin-compatible alternative to LX9FL916?

No official replacement is listed in the available records. The best path is to source the original LX9FL916 through surplus channels or to retrofit the contactor assembly with a current-production TeSys F coil of matching voltage — verify the coil mounting and terminal arrangement before ordering.

What is the control voltage range for LX9FL916?

The rated control circuit voltage is 38...41 V DC. Operational limits are 0.85...1.1 Uc at 55 °C, and drop-out occurs at 0.3...0.5 Uc at 55 °C.