Schneider Electric LX9FL929 — Contactor & Starter Coils

Schneider LX9FL929 TeSys F Contactor Coil, 169-186 V DC

MPNLX9FL929
Active

Schneider Electric TeSys F series, LX9FL929, specific contactor coil, 169-186 V DC, low consumption.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LX9FL929 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FL
Coil technologyWithout built-in suppressor module

Electrical

LX9FL929 — Electrical
ParameterValue
Control circuit voltage [Uc]169...186 V DC
Control circuit typeAC 40...400 Hz low consumption DC low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.3...0.5 Uc 131 °F (55 °C))

Power & Thermal

LX9FL929 — Power & Thermal
ParameterValue
Inrush power (W)733 W 68 °F (20 °C))
Hold-in power (W)48 W 68 °F (20 °C)
Heat dissipation22.8...27.8 W

Performance & Durability

LX9FL929 — Performance & Durability
ParameterValue
Operating time60 ms opening 20 ms closing
Max. operating rate1800 cyc/h 158 °F (70 °C)
Mechanical durability5 Mcycles

Environmental

LX9FL929 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX9FL929 is a specific replacement coil for TeSys F contactors, carrying a 169 to 186 V DC control circuit voltage. This is a low-consumption variant, meaning the hold-in power draw settles at 48 W at 68 °F (20 °C) after the inrush peak of 733 W at the same temperature. The coil is supplied without a built-in suppressor module, so you will need to fit an external RC snubber or free-wheeling diode across the terminals if the control circuit drives inductive loads that could cause back-EMF spikes.

Switching times and thermal budget

Opening time is rated at 60 ms, closing at 20 ms — fast enough for most motor-start and isolation sequences in a panel. Heat dissipation runs between 22.8 and 27.8 W, so factor that into the enclosure's thermal rise calculation; a densely packed cabinet may need forced ventilation or a larger panel to stay within the -5 to 55 °C ambient operating range.

Frequently asked questions

What is the control voltage for this coil?

The control circuit voltage is 169 to 186 V DC. The operational limits are 0.85 to 1.1 times Uc at 131 °F (55 °C), and dropout occurs between 0.3 and 0.5 times Uc at the same temperature.

Does this coil include a built-in suppressor module?

No. The coil technology is listed as 'Without built-in suppressor module'. You must add an external suppression device (RC snubber or diode) if the control circuit can generate inductive kickback.

What is the operating temperature range for this coil?

The ambient air temperature for operation is -5 to 55 °C (23 to 131 °F). The maximum operating rate of 1800 cycles per hour is specified at 70 °C (158 °F).