Specifications

LX9FL935 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FL
Coil technologyWithout built-in suppressor module
LX9FL935 — Electrical
ParameterValue
Control circuit voltage [Uc]380...400 V AC 40...400 Hz 380...400 V DC
Control circuit typeAC 40...400 Hz low consumption DC low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.25...0.5 Uc 131 °F (55 °C))
Coil resistance (avg.)163 Ohm inrush 68 °F (20 °C) 1360 Ohm holding 68 °F (20 °C)
Coil inductance (closed circuit)8.8 H
LX9FL935 — Power & Thermal
ParameterValue
Inrush power (VA)830 VA 40...400 Hz (at 68 °F (20 °C))
Hold-in power (VA)47 VA 40...400 Hz (at 68 °F (20 °C))
Heat dissipation22.8...27.8 W
LX9FL935 — Performance & Durability
ParameterValue
Operating time60 ms opening 50 ms closing
Max. operating rate1800 cyc/h 158 °F (70 °C)
Mechanical durability5 Mcycles
LX9FL935 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

Overview

The LX9FL935 is a Schneider TeSys F specific contactor coil, order code LX9FL935, rated for 400 V AC at 40-400 Hz low consumption, drawing 830 W and consuming 47 W in steady state. It is designed for use with TeSys F LC1F contactors, specifically the LC1F630 frame, and mates with the DR5TE rectifier. The coil carries no built-in suppressor module and is packaged as a single PCE unit.

This coil energizes the LC1F contactor armature when 400 V AC is applied across its terminals, drawing 830 W during inrush and settling to 47 W holding power. The AC 40-400 Hz low-consumption design keeps thermal rise in check across a wide frequency range. The coil operates with a 60 ms response time and is rated for 1800 cycles per hour at 70 °C ambient. Mechanical life is 5 Mcycles. Heat dissipation runs 22.8 to 27.8 W, so panel ventilation should account for that continuous load. Compatibility extends to the DR5TE rectifier and LC1F630 contactor; the coil is a drop-in replacement for those specific frames. No built-in suppressor means an external RC snubber or varistor may be needed for inductive load switching.