Skip to main content
Schneider Electric LX9FL938 — Contactor & Starter Coils

LX9FL938 TeSys Contactor Coil, 440-460V AC/DC, 60ms Open

MPNLX9FL938
Active

Schneider Electric TeSys F series, LX9FL938 specific contactor coil, 440-460 V AC 40-400 Hz / DC low consumption, 60 ms opening 50 ms closing.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX9FL938 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FL
Coil technologyWithout built-in suppressor module
LX9FL938 — Electrical
ParameterValue
Control circuit voltage [Uc]440...460 V DC 440...460 V AC 40...400 Hz
Control circuit typeAC 40...400 Hz low consumption DC low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.25...0.5 Uc 131 °F (55 °C))
Coil resistance (avg.)312 Ohm inrush 68 °F (20 °C) 2510 Ohm holding 68 °F (20 °C)
Coil inductance (closed circuit)17 H
LX9FL938 — Power & Thermal
ParameterValue
Inrush power (VA)830 VA 40...400 Hz (at 68 °F (20 °C))
Hold-in power (VA)47 VA 40...400 Hz (at 68 °F (20 °C))
Heat dissipation22.8...27.8 W
LX9FL938 — Performance & Durability
ParameterValue
Operating time60 ms opening 50 ms closing
Max. operating rate1800 cyc/h 158 °F (70 °C)
Mechanical durability5 Mcycles
LX9FL938 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

Coil for the TeSys F line

The LX9FL938 is a specific contactor coil in the TeSys F range, designed to drive the main contactor armature. It accepts a control voltage of 440-460 V AC (40-400 Hz) or DC, with a low-consumption hold circuit that drops inrush from 830 VA to 47 VA once the contactor seals. Opening time is 60 ms, closing time 50 ms — fast enough for most motor-start and power-switching sequences in industrial panels. The coil carries no built-in suppressor module, so you'll want to add a flyback diode or RC snubber across the terminals if the control circuit drives inductive loads like a PLC output. The hold-in power consumption sits at 47 VA, and heat dissipation runs 22.8-27.8 W — factor that into your enclosure thermal budget if the panel is tight.

Frequently asked questions

What control voltage does the LX9FL938 coil accept?

The coil accepts 440-460 V AC at 40-400 Hz, or 440-460 V DC. The operating range is 0.85-1.1 Uc at 55 °C, with dropout between 0.25-0.5 Uc.

Does the LX9FL938 include a built-in coil suppression module?

No — the coil technology is listed as 'without built-in suppressor module'. You need to add external suppression (flyback diode for DC, RC snubber for AC) if the control circuit is sensitive to voltage spikes.

What is the operating temperature range for this coil?

The ambient air temperature for operation is -5 to 55 °C (23-131 °F).