Skip to main content
Schneider Electric LXM16DU15M2X — Servo Drives

Schneider Electric LXM16DU15M2X Easy Lexium 16 Servo Drive

MPNLXM16DU15M2X
Active

Schneider Electric LXM16DU15M2X Easy Lexium 16 motion servo drive, single-phase 200-240 V, 1.5 kW nominal power, 8 kHz switching frequency, compact housing, no EMC filter.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LXM16DU15M2X — Identification
ParameterValue
Device short nameLXM16D
Product rangeEasy Lexium 16
Product typeMotion servo drive
LXM16DU15M2X — Electrical
ParameterValue
Rated supply voltage220 V (- 15...10 %) for single phase
Supply voltage limits200...240 V single phase

Product details

What the 1.5 kW rating means for your axis

The LXM16DU15M2X delivers 1.5 kW nominal power at 220 V with an 8 kHz switching frequency — the switching rate is fixed, not adjustable, so the motor winding inductance and cable capacitance must be compatible with that carrier frequency to avoid over-heating the drive output stage. Continuous output current is 8.3 A, with a 3-second peak of 30 A at 220 V — that 3.6× overload margin handles the acceleration and deceleration transients typical of pick-and-place or indexing axes without oversizing the drive. Line current draw is 14.4 A at 144.8 % of rated load on single-phase 220 V — this is the input current the upstream branch circuit and wiring must be sized for, not the motor current.

Single-phase supply, no EMC filter — plan the panel accordingly

This drive runs on 200-240 V single-phase only — no three-phase input option. The supply voltage tolerance is -15 % to +10 % at 220 V nominal, with a line frequency range of 47.5-63 Hz. The LXM16DU15M2X ships without an internal EMC filter (per the description). An external filter must be added at the panel level to meet conducted emission limits for CE or other regulatory marks — factor the filter footprint and cost into the BOM. Maximum leakage current is 3.5 mA — this is the ground-leakage figure for sizing the upstream RCD or GFCI. Overvoltage category III means the drive is rated for fixed-installation distribution-level transients.

Active production — BOM-fit and sourcing

This is a qualified part for serial-production BOMs that need supply continuity. Part of the Easy Lexium 16 family, compact housing format — the drive is sized for DIN-rail or panel mounting in control cabinets where space is constrained. No official successor or cross-reference exists; the LXM16D short name identifies the platform.

Frequently asked questions

What is the line current draw of LXM16DU15M2X?

The line current is 14.4 A at 144.8 % of rated load on single-phase 220 V supply. This is the input current for sizing the branch circuit and upstream protection.

Does LXM16DU15M2X include an internal EMC filter?

No, this variant ships without an EMC filter. An external filter must be added at the panel level to meet conducted emission compliance requirements.

MPN
LXM16DU15M2X