What the 1.5 kW rating means for your axis
The LXM16DU15M2X delivers 1.5 kW nominal power at 220 V with an 8 kHz switching frequency — the switching rate is fixed, not adjustable, so the motor winding inductance and cable capacitance must be compatible with that carrier frequency to avoid over-heating the drive output stage. Continuous output current is 8.3 A, with a 3-second peak of 30 A at 220 V — that 3.6× overload margin handles the acceleration and deceleration transients typical of pick-and-place or indexing axes without oversizing the drive. Line current draw is 14.4 A at 144.8 % of rated load on single-phase 220 V — this is the input current the upstream branch circuit and wiring must be sized for, not the motor current.
Single-phase supply, no EMC filter — plan the panel accordingly
This drive runs on 200-240 V single-phase only — no three-phase input option. The supply voltage tolerance is -15 % to +10 % at 220 V nominal, with a line frequency range of 47.5-63 Hz. The LXM16DU15M2X ships without an internal EMC filter (per the description). An external filter must be added at the panel level to meet conducted emission limits for CE or other regulatory marks — factor the filter footprint and cost into the BOM. Maximum leakage current is 3.5 mA — this is the ground-leakage figure for sizing the upstream RCD or GFCI. Overvoltage category III means the drive is rated for fixed-installation distribution-level transients.
Active production — BOM-fit and sourcing
This is a qualified part for serial-production BOMs that need supply continuity. Part of the Easy Lexium 16 family, compact housing format — the drive is sized for DIN-rail or panel mounting in control cabinets where space is constrained. No official successor or cross-reference exists; the LXM16D short name identifies the platform.