Skip to main content
Schneider Electric LXM16MU02M2X

Schneider LXM16MU02M2X Easy Lexium 16 Servo Drive, 0.2 kW

MPN LXM16MU02M2X
Active

Schneider Electric LXM16MU02M2X motion servo drive, Easy Lexium 16 series, 0.2 kW nominal power at 220 V, single-phase 200-240 V supply, 1.6 A continuous output, 8 kHz switching frequency, Modbus communication, compact housing.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LXM16MU02M2X specifications
ParameterValue
Main product or component typeMotion servo drive
Voltage1000...2000 m with current derating
Current2.5 A 206.1 % at 220 V, single phase
Frequency8 kHz

Product details

Single-phase servo drive for light-duty positioning

The LXM16MU02M2X is a 0.2 kW motion servo drive from Schneider Electric's Easy Lexium 16 series, designed for single-phase 200-240 V supply lines. It delivers 1.6 A continuous output current and can supply 7.5 A peak for 3 seconds, which covers acceleration and deceleration transients on small positioning axes. The drive draws 2.5 A line current at 220 V single phase — this is the figure to use when sizing the upstream branch circuit protection and the supply transformer for a multi-axis cabinet.

Power stage and switching frequency

Switching frequency is fixed at 8 kHz, which balances motor audible noise against thermal losses in the output stage. At this frequency the drive delivers its full 200 W continuous power at 220 V. The supply frequency tolerance is 50/60 Hz ±5 %, with the network frequency range extending from 47.5 to 63 Hz — the drive locks to the incoming line frequency within that window.

Supply and grounding requirements

Rated supply voltage is 220 V (-15 % / +10 %) single phase, with absolute limits of 200-240 V. Overvoltage category III means the drive is designed for fixed installation downstream of the building's main distribution board, not for outlet-plug connection. Maximum leakage current is 3.5 mA — this is within the threshold for standard 30 mA RCDs, but the drive should be on a dedicated circuit if multiple units share a common protective device.

The drive ships as a compact housing unit with Modbus communication onboard. No EMC filter is integrated — plan for an external filter if the installation must meet conducted emission limits for the single-phase supply.

MPN