Schneider Electric MGN19746 — Residual Current Breakers (RCCB/RCBO)

Schneider MGN19746 Acti9 DCP Vigi RCBO, 25 A, 30 mA, Curve B

MPNMGN19746
Obsolete

Schneider Electric Acti9 DCP Vigi RCBO, MGN19746, 4P, 25 A, 30 mA, curve B, 6 kA breaking capacity, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN19746 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON, OFF, fault trip
MGN19746 — Electrical Ratings
ParameterValue
Rated current (In)25 A
Rated operational voltage (Ue)380...415 V AC 50 Hz
Poles description4P
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV
Electrical durability10000 cycles
Mechanical durability (operating cycles)20000 cycles
MGN19746 — Identification
ParameterValue
Product nameActi9 DCP Vigi
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameDCP N Vigi
MGN19746 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules8
Terminal connectionsTunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible
Wire stripping length12 mm for top or bottom connection
Terminal tightening torque2 N.m top or bottom
Width72 mm
Height85 mm
Depth76 mm
MGN19746 — Environmental
ParameterValue
Operating ambient temperature-25...40 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Relative humidity95 % at 55 °C
Tropicalisation2
MGN19746 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1

Product details

It combines a 25 A thermal-magnetic trip (curve B, 3–5× In magnetic threshold) with integrated 30 mA earth-leakage protection in a single DIN-rail module, rated for 6 kA breaking capacity at 380–415 V AC per EN/IEC 61009-2-1.

The 30 mA earth-leakage threshold provides personnel protection (30 mA is the standard for shock-risk circuits per IEC 60364). Breaking capacity of 6 kA Icn at 380–415 V AC (6 kA Icu per EN/IEC 60947-2) means it safely clears fault currents up to 6 kA without welding contacts or cascading upstream. That's adequate for most commercial and light-industrial distribution boards fed by a typical 400 V transformer under 630 kVA; for higher fault levels you'd step up to a 10 kA or 15 kA device in the same Acti9 family. The integrated earth-leakage block saves a DIN space compared to a separate MCB + RCCD combination — one 4-module-wide unit (72 mm, 8 × 9 mm pitches) instead of two. Clip-on mounting to standard DIN rail, tunnel terminals accepting up to 35 mm² rigid, and a toggle with ON/OFF/fault-trip local signalling make it a straightforward swap into an existing Acti9 board.

Mounts on standard DIN rail via clip-on, occupying 72 mm width (8 × 9 mm pitches) in a modular enclosure. Depth of 76 mm and height of 85 mm fit standard Acti9 distribution boards and most generic enclosures. IP20 on the body, IP40 within the modular enclosure — suitable for dry indoor panels, not washdown zones. Tunnel-type terminals top and bottom accept 1–35 mm² rigid or 1–25 mm² flexible, with a stripping length of 12 mm and tightening torque of 2 N·m. The 4-pole configuration protects all four poles (, L2, L3, N) with both overcurrent and earth-leakage monitoring — no need for a separate neutral protection module.

Frequently asked questions

Where can I buy MGN19746?

MGN19746 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of MGN19746?

6 kA Icn at 380–415 V AC per EN/IEC 61009-2-1, and 6 kA Icu per EN/IEC 60947-2.

What does the 30 mA earth-leakage sensitivity mean?

30 mA is the standard threshold for personnel protection against electric shock in final circuits per IEC 60364 — it trips fast enough to prevent ventricular fibrillation.

Does MGN19746 fit a standard DIN rail?

Yes, it clips onto standard DIN rail (35 mm) and occupies 72 mm width (8 × 9 mm pitches).