Schneider Electric MGN19752 — Residual Current Breakers (RCCB/RCBO)

MGN19752 Acti9 DCP Vigi RCBO, 10 A, 30 mA, C-curve, 2P

MPNMGN19752
Obsolete

Schneider Electric Acti9 DCP Vigi RCBO, MGN19752, 10 A, 30 mA earth leakage, C-curve, 2-pole, 10 kA breaking capacity, DIN rail clip-on.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN19752 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON, OFF, fault trip
MGN19752 — Electrical Ratings
ParameterValue
Rated current (In)10 A
Rated operational voltage (Ue)220...240 V AC 50 Hz
Poles description2P
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV
Electrical durability10000 cycles
Mechanical durability (operating cycles)20000 cycles
MGN19752 — Identification
ParameterValue
Product nameActi9 DCP Vigi
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameDCP H Vigi
MGN19752 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible
Wire stripping length12 mm for top or bottom connection
Terminal tightening torque2 N.m top or bottom
Width36 mm
Height85 mm
Depth76 mm
MGN19752 — Environmental
ParameterValue
Operating ambient temperature-25...40 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Relative humidity95 % at 55 °C
Tropicalisation2
MGN19752 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1

Product details

The MGN19752 is a 2-pole residual current breaker with overcurrent protection (RCBO) from the Schneider Electric Acti9 DCP Vigi range, combining a 10 A thermal-magnetic C-curve MCB with integrated 30 mA earth-leakage protection in a single 36 mm wide DIN-rail module. The 10 kA breaking capacity (Icn at 220-240 V AC, 50 Hz) per EN/IEC 61009-2-1 and 10 kA Icu per EN/IEC 60947-2 gives it enough fault-clearing headroom for most residential and light commercial distribution boards without forcing an upstream breaker upgrade.

The 30 mA earth-leakage sensitivity is the standard for personal protection against indirect contact in IEC 60364 installations — it's what you'd specify for socket-outlet circuits or general-purpose final subcircuits where the fault path could go through a person. Integrated earth leakage means you don't need a separate RCD module upstream or downstream; the RCBO handles both overcurrent and ground-fault in one device, which saves a DIN position and simplifies wiring. The thermal-magnetic trip technology is field-proven and unaffected by harmonics that can confuse electronic trip units on some VFD-fed circuits.

Clip-on mounting to DIN rail, no screws needed for the rail attachment — push on until the latch clicks. Tunnel-type terminals top and bottom accept 1 to 35 mm² rigid or 1 to 25 mm² flexible; strip 12 mm and tighten to 2 N·m. The 76 mm depth means it sits flush with other Acti9 devices, so the gland plate clearance you already have for a 4-module board is fine. IP20 on the body (fingertip-safe), IP40 inside a modular enclosure — standard for distribution boards, not for washdown zones. Non-padlockable, so if your site requires lockout provisions, plan for a separate hasp on the board door or a padlockable cover. Local signalling (ON, OFF, fault trip) and a contact position indicator let you verify state without a meter — helpful during fault isolation when the line electrician needs to confirm the RCBO has actually opened.

The tropicalisation class 2 rating means it has passed damp-heat cyclic testing (95% RH at 55 °C) per IEC 60068-2-30 — suitable for coastal or high-humidity installations without derating. Limitation class 2 (energy-limiting) per IEC 60898-1 means it restricts let-through energy under fault conditions, which helps with downstream coordination. The 8/20 µs impulse withstand of 250 A per EN/IEC 61009-2-1 confirms it handles surge currents from switching transients or nearby lightning without nuisance tripping. RoHS and REACH compliance documentation is available from the manufacturer; CE marking applies for EU markets.

Frequently asked questions

What is the breaking capacity of MGN19752?

The MGN19752 has a 10 kA Icn at 220-240 V AC 50 Hz per EN/IEC 61009-2-1 and a 10 kA Icu at the same voltage per EN/IEC 60947-2. This is sufficient for most residential and light commercial distribution boards.

What is the earth leakage sensitivity of MGN19752?

The MGN19752 has an integrated 30 mA earth-leakage protection, which is the standard sensitivity for personal protection against indirect contact in IEC 60364 installations.

What terminals does MGN19752 use and what wire sizes does it accept?

The MGN19752 uses tunnel-type terminals top and bottom, accepting 1 to 35 mm² rigid or 1 to 25 mm² flexible conductors. Strip length is 12 mm and tightening torque is 2 N·m.

Where can I buy MGN19752 and how is it quoted?

The MGN19752 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at the time of quote.