Skip to main content
Schneider Electric MGN25082

MGN25082 C60H MCB, D Curve 3 A, 15 kA at 240 V

MPN MGN25082
Obsolete

Schneider Electric C60H Multi9 miniature circuit-breaker, 1P, D curve, 3 A, 15 kA at 240 V AC, thermal-magnetic, DIN rail mount, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN25082 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage240 V AC 50/60 Hz phase to neutral
Breaking capacity15 kA Icu at 240 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2 4 kA Icu at 415 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C

All specifications

MGN25082 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
Depth73 mm
Width18 mm
Height81 mm
Electrical life cycles10000 cycles conforming to EN/IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The MGN25082 is a C60H miniature circuit-breaker from the Multi9 range, a single-pole thermal-magnetic unit rated 3 A at 50 °C with a D tripping curve. It breaks up to 15 kA at 240 V AC phase-to-neutral, tested to EN/IEC 60947-2.

D curve — why it matters for motor and transformer circuits

The D curve trips magnetically at 12 x In (±20 %), so for this 3 A unit the instantaneous trip threshold sits between roughly 28.8 A and 43.2 A. That wide magnetic window lets it ride through the inrush of small motors, transformers, or solenoid loads without nuisance tripping — a D curve is the usual choice for motor branch circuits or inductive loads where a C curve would drop out on start-up. The thermal element handles the overload protection; the magnetic element clears the short.

Snaps onto 35 mm symmetrical DIN rail, fixed mounting. At 18 mm wide (2 x 9 mm pitches), it occupies one standard module slot — easy to fit into a crowded enclosure without re-spacing adjacent breakers.

MPN
MGN25082