Skip to main content
Schneider Electric MGN25108 — 2-Pole MCB (DIN Rail)

MGN25108 C60H MCB, 2P D-curve 1A, 30 kA Icu at 240 V

MPNMGN25108
Obsolete

Schneider Electric C60H Multi9 miniature circuit-breaker, MGN25108, 2-pole, D-curve, 1 A rated current, 30 kA Icu at 240 V AC, thermal-magnetic trip, DIN-rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGN25108 — Identification
ParameterValue
Product nameC60
Product rangeC60
Series / familyMulti9
Device short nameC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
MGN25108 — Electrical
ParameterValue
Rated current [In]1 A at 50 °C conforming to EN/IEC 60947-2
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase
Network type (AC/DC)AC
Network frequency50/60 Hz
MGN25108 — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit12 x In +/- 20 %
Breaking capacity (Icu)30 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2
Rated service breaking capacity [Ics]15 kA 50 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
Suitable for isolationYes conforming to EN/IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGN25108 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height81 mm
Depth73 mm
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Terminal connectionsTunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end
Terminal tightening torquePower circuit: 2 N.m
Comb busbar / distribution block compatibilityTop or bottom: YES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
MGN25108 — Environmental
ParameterValue
Operating temperature range-30...70 °C
Storage temperature range-40...80 °C
MGN25108 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2

Product details

The MGN25108 is a Schneider Electric C60H miniature circuit-breaker from the Multi9 range, rated 1 A at 50 °C with a D-curve trip characteristic. The 2-pole thermal-magnetic design covers both line and neutral protection in a single 36 mm wide DIN-rail module.

The D-curve trips magnetically between 10× and 14× In (12× In ±20 %), so it tolerates high inrush without nuisance tripping — typical for motor loads, transformers, or welding equipment. At 415 V the Icu drops to 15 kA, Ics to 7.5 kA.

The 36 mm width (4 × 9 mm pitches) fits standard distribution boards. IP20 finger-safe front, pollution degree 3 rated — fine for clean indoor panels, not for wet environments. Ambient operating range -30…70 °C, storage -40…80 °C.

Frequently asked questions

What compliance documentation does Schneider Electric provide for MGN25108?

The MGN25108 is certified to EN/IEC 60947-2, which covers the safety and performance standards for miniature circuit-breakers. The manufacturer typically provides a Declaration of Conformity for CE marking and may supply RoHS/REACH declarations upon request.

Where can I buy MGN25108 and how is it quoted?

The MGN25108 is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — we confirm both at quote time.

MPN
MGN25108