Schneider Electric C60H Multi9 miniature circuit breaker, MGN25119, 2-pole, 25 A, D curve, 30 kA breaking capacity at 240 V AC, thermal-magnetic trip, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGN25119 — Identification
ParameterValue
Product nameC60
Product rangeC60
Series / familyMulti9
Device short nameC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
MGN25119 — Electrical
ParameterValue
Rated current [In]25 A at 50 °C conforming to EN/IEC 60947-2
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase
Network type (AC/DC)AC
Network frequency50/60 Hz
MGN25119 — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit12 x In +/- 20 %
Breaking capacity (Icu)30 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2
Rated service breaking capacity [Ics]15 kA 50 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
Suitable for isolationYes conforming to EN/IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGN25119 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height81 mm
Depth73 mm
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Terminal connectionsTunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end
Terminal tightening torquePower circuit: 2 N.m
Comb busbar / distribution block compatibilityTop or bottom: YES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
MGN25119 — Environmental
ParameterValue
Operating temperature range-30...70 °C
Storage temperature range-40...80 °C
MGN25119 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2

Product details

The Schneider Electric MGN25119 is a C60H miniature circuit breaker from the Multi9 range, rated 25 A at 50 °C per EN/IEC 60947-2, with a D trip curve and 2 protected poles. It is a thermal-magnetic device, category A, designed for distribution applications where high inrush currents (motor starts, transformer primaries, lighting ballasts) demand the D curve's wider magnetic trip threshold of 12 x In ±20 %.

The C60H frame delivers 30 kA Icu at 240 V AC phase-to-phase, 15 kA at 415 V, and 10 kA at 440 V — all per EN/IEC 60947-2. The corresponding Ics (service breaking capacity) is 50 % of Icu at each voltage level: 15 kA at 240 V, 7.5 kA at 415 V, 5 kA at 440 V.

IP20 finger-safe front.

Frequently asked questions

Where can I buy MGN25119 and how do I get a price?

The MGN25119 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the closest alternative to MGN25119 in the C60 family?

Within the C60 range, the C60H (MGN25119) sits above the C60N in breaking capacity. The C60N offers lower Icu ratings (typically 15 kA at 240 V vs. 30 kA for the C60H). If your fault current is under 15 kA, the C60N is a cost-effective drop-in; above that, the C60H is the correct choice. Both share the same DIN footprint, terminal range, and D-curve options.

What is MGN25119's listed depth?

The MGN25119 has a depth of 73 mm.

What is MGN25119's listed range?

The MGN25119 belongs to the Multi9 range, product name C60.

What compliance documentation does Schneider provide for MGN25119?

The MGN25119 is certified to EN/IEC 60947-2, with pollution degree 3, and is suitable for isolation per that standard. It carries IP20 protection. Specific RoHS/REACH/UL documentation should be requested at quote time, as those declarations are not listed in the standard spec set.