Schneider Electric MGN25120

Schneider Electric MGN25120 C60H MCB, D Curve, 32 A, 2P, 30

MPN MGN25120
Obsolete

Schneider Electric C60H Multi9 miniature circuit breaker, MGN25120, 2-pole, D curve, 32 A rated current, 30 kA breaking capacity at 240 V AC, EN/IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN25120 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase
Breaking capacity30 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C

All specifications

MGN25120 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles10000 cycles conforming to EN/IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The Schneider Electric MGN25120 is a C60H miniature circuit breaker from the Multi9 range, rated 32 A at 50 °C per EN/IEC 60947-2 with a D trip curve.

Breaking capacity and duty

Breaking capacity reaches 30 kA Icu at 240 V AC phase-to-phase, 15 kA at 415 V, and 10 kA at 440 V — all per EN/IEC 60947-2. The rated service breaking capacity (Ics) is 50 % of Icu at each voltage level, so after clearing a fault at 15 kA at 240 V the breaker remains usable, not just safe. That matters for panel builders who want to avoid replacing a breaker after a single fault event.

Snaps onto a 35 mm symmetrical DIN rail, fixed mounting, 2-pole width of 36 mm (4 x 9 mm pitches). Depth is 73 mm, height 81 mm. Tunnel terminals accept 1.5…35 mm² flexible or rigid wire; strip length 14 mm, torque to 3.5 N·m. IP20 finger-safe front. The compact 36 mm footprint leaves room alongside other Multi9 devices in a distribution board.

MPN