Skip to main content
Schneider Electric MGN60509 — 1-Pole MCB (DIN Rail)

MGN60509 C60N MCB, D Curve 4 A, 1P, 10 kA

MPNMGN60509
Obsolete

Schneider Electric C60N Multi9 miniature circuit-breaker, MGN60509, D curve, 4 A rated, 1-pole, 10 kA breaking capacity at 240 V AC, 35 mm DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGN60509 — Identification
ParameterValue
Product nameC60
Product / component typeMiniature circuit-breaker
Product rangeMulti9
Device short nameC60N
Poles description1P
Number of protected poles1
Device applicationDistribution
MGN60509 — Electrical & Protection
ParameterValue
Rated current (In)4 A at 50 °C conforming to EN/IEC 60947-2
Rated operational voltage (Ue)240 V AC 50/60 Hz phase to neutral
Tripping curve codeD
Magnetic tripping limit12 x In +/- 20 %
Breaking capacity (Icu / AIR)10 kA Icu at 240 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2 3 kA Icu at 415 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
MGN60509 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Width18 mm
Height81 mm
Depth73 mm
Tightening torque (by circuit)Power circuit: 2 N.m
MGN60509 — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to EN/IEC 60947-2
MGN60509 — Approvals
ParameterValue
Conformity standardsEN/IEC 60947-2

Product details

The MGN60509 is a C60N miniature circuit-breaker from the Multi9 range, rated 4 A at 50 °C with a D tripping curve (12 x In magnetic limit). Breaking capacity is 10 kA Icu at 240 V AC phase-to-neutral, with a service breaking capacity Ics of 7.5 kA (75 %) at the same voltage — enough for most distribution sub-panels in commercial or light industrial installations. At 415 V AC the Icu drops to 3 kA, so this is a 240 V line-to-neutral part, not a 400 V three-phase breaker.

IP20 finger-safe terminals — intended for enclosed panel use, not washdown. Rated for pollution degree 3 (conductive or dry non-conductive pollution), operating ambient -30 to 70 °C, storage -40 to 80 °C. Electrical endurance 10,000 cycles, mechanical 20,000 cycles. Local ON/OFF indication and contact position indicator standard.

Frequently asked questions

What is the breaking capacity of MGN60509?

10 kA Icu at 240 V AC phase-to-neutral, 3 kA Icu at 415 V AC phase-to-neutral, both per EN/IEC 60947-2. Service breaking capacity Ics is 7.5 kA (75 %) at 240 V.

What is the D curve magnetic trip threshold?

The magnetic trip fires at 12 x In ±20 %, so for this 4 A breaker the instantaneous trip point is nominally 48 A.

Where can I buy MGN60509?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN